net: phy: micrel: ksz9131 led errata workaround

Micrel KSZ9131 PHY LED behavior is not correct when configured in
Individual Mode, LED1 (Activity LED) is in the ON state when there is
no-link.

Workaround this by setting bit 9 of register 0x1e after verifying that
the LED configuration is Individual Mode.

This issue is described in KSZ9131RNX Silicon Errata DS80000693B [*]
and according to that it will not be corrected in a future silicon
revision.

[*] https://ww1.microchip.com/downloads/en/DeviceDoc/KSZ9131RNX-Silicon-Errata-and-Data-Sheet-Clarification-80000863B.pdf

Signed-off-by: Francesco Dolcini <francesco.dolcini@toradex.com>
Reviewed-by: Philippe Schenker <philippe.schenker@toradex.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>