net: dsa: microchip: ksz8: add MTU configuration support
authorOleksij Rempel <o.rempel@pengutronix.de>
Mon, 5 Dec 2022 05:22:30 +0000 (06:22 +0100)
committerPaolo Abeni <pabeni@redhat.com>
Wed, 7 Dec 2022 10:57:58 +0000 (11:57 +0100)
commit29d1e85f45e03c9fd1b8985f983f33c021e130c8
treee4f31b4ba722611b104da68357916df154068a44
parent6f1b986a43ce9aa67b11a7e54ac75530705d04e7
net: dsa: microchip: ksz8: add MTU configuration support

Make MTU configurable on KSZ87xx and KSZ88xx series of switches.

Before this patch, pre-configured behavior was different on different
switch series, due to opposite meaning of the same bit:
- KSZ87xx: Reg 4, Bit 1 - if 1, max frame size is 1532; if 0 - 1514
- KSZ88xx: Reg 4, Bit 1 - if 1, max frame size is 1514; if 0 - 1532

Since the code was telling "... SW_LEGAL_PACKET_DISABLE, true)", I
assume, the idea was to set max frame size to 1532.

With this patch, by setting MTU size 1500, both switch series will be
configured to the 1532 frame limit.

This patch was tested on KSZ8873.

Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de>
Acked-by: Arun Ramadoss <arun.ramadoss@microchip.com>
Reviewed-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Paolo Abeni <pabeni@redhat.com>
drivers/net/dsa/microchip/ksz8.h
drivers/net/dsa/microchip/ksz8795.c
drivers/net/dsa/microchip/ksz8795_reg.h
drivers/net/dsa/microchip/ksz_common.c
drivers/net/dsa/microchip/ksz_common.h