phy: qcom-qmp-combo: fix sc8180x reset
commit
910dd4883d757af5faac92590f33f0f7da963032 upstream.
The SC8180X has two resets but the DP configuration erroneously
described only one.
In case the DP part of the PHY is initialised before the USB part (e.g.
depending on probe order), then only the first reset would be asserted.
Fixes: 1633802cd4ac ("phy: qcom: qmp: Add SC8180x USB/DP combo")
Cc: stable@vger.kernel.org # 5.15
Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org>
Signed-off-by: Johan Hovold <johan+linaro@kernel.org>
Link: https://lore.kernel.org/r/20221114081346.5116-4-johan+linaro@kernel.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>