iio: pressure: dps310: Reset chip after timeout
commit
7b4ab4abcea4c0c10b25187bf2569e5a07e9a20c upstream.
The DPS310 chip has been observed to get "stuck" such that pressure
and temperature measurements are never indicated as "ready" in the
MEAS_CFG register. The only solution is to reset the device and try
again. In order to avoid continual failures, use a boolean flag to
only try the reset after timeout once if errors persist.
Fixes: ba6ec48e76bc ("iio: Add driver for Infineon DPS310")
Cc: <stable@vger.kernel.org>
Signed-off-by: Eddie James <eajames@linux.ibm.com>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Link: https://lore.kernel.org/r/20220915195719.136812-3-eajames@linux.ibm.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>