iio: adc: ti-lmp92064: add buffering support
Enable buffered reading of samples from the LMP92064 ADC.
The main benefit of this change is being able to read out current and
voltage measurements in a single transfer, allowing instantaneous power
measurements.
Reads into the buffer can be triggered by any software triggers, e.g.
the iio-trig-hrtimer:
$ mkdir /sys/kernel/config/iio/triggers/hrtimer/my-trigger
$ cat /sys/bus/iio/devices/iio\:device3/name
lmp92064
$ iio_readdev -t my-trigger -b 16 iio:device3 | hexdump
WARNING: High-speed mode not enabled
0000000 0000 0176 0101 0001 5507 abd5 7645 1768
0000010 0000 016d 0101 0001 ee1e ac6b 7645 1768
...
Signed-off-by: Leonard Göhrs <l.goehrs@pengutronix.de>
Reviewed-by: Nuno Sa <nuno.sa@analog.com>
Link: https://lore.kernel.org/r/20230707063635.1496437-1-l.goehrs@pengutronix.de
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>