media: imx335: Limit analogue gain value
The sensor gain (both analog and digital) are controlled by a
single gain value where:
- 0dB to 30dB correspond to analog gain
- 30.3dB to 72dB correspond to digital gain
(with 0.3dB step)
Hence, limit the analogue gain value to 100.
For digital gain, support can be added later if needed.
Signed-off-by: Umang Jain <umang.jain@ideasonboard.com>
Reviewed-by: Kieran Bingham <kieran.bingham@ideasonboard.com>
Reviewed-by: Tommaso Merciai <tomm.merciai@gmail.com>
Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>