hwmon: (nct6775) Fix fan speed set failure in automatic mode
authorXing Tong Wu <xingtong.wu@siemens.com>
Tue, 21 Nov 2023 08:16:04 +0000 (16:16 +0800)
committerGuenter Roeck <linux@roeck-us.net>
Mon, 11 Dec 2023 14:21:00 +0000 (06:21 -0800)
commit8b3800256abad20e91c2698607f9b28591407b19
treea1221479046f20b59e2c9587db866e05463bca2b
parentff629afe7ffdfdfee15c75e9a22c67d316338cc5
hwmon: (nct6775) Fix fan speed set failure in automatic mode

Setting the fan speed is only valid in manual mode; it is not possible
to set the fan's speed in automatic mode.
Return error when attempting to set the fan speed in automatic mode.

Signed-off-by: Xing Tong Wu <xingtong.wu@siemens.com>
Link: https://lore.kernel.org/r/20231121081604.2499-3-xingtong_wu@163.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
drivers/hwmon/nct6775-core.c