iio: kx022a: Fix acceleration value scaling
authorMatti Vaittinen <mazziesaccount@gmail.com>
Thu, 19 Oct 2023 13:23:56 +0000 (16:23 +0300)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Thu, 16 Nov 2023 19:35:41 +0000 (19:35 +0000)
commit92bfa4ab1b79be95c4f52d13f5386390f0a513c2
treed9caffd64ad352b04b0231d00853638efa74d2df
parentb85ea95d086471afb4ad062012a4d73cd328fa86
iio: kx022a: Fix acceleration value scaling

The IIO ABI mandates acceleration values from accelerometer to be
emitted in m/s^2. The KX022A was emitting values in micro m/s^2.

Fix driver to report the correct scale values.

Signed-off-by: Matti Vaittinen <mazziesaccount@gmail.com>
Reported-by: Jagath Jog J <jagathjog1996@gmail.com>
Fixes: 7c1d1677b322 ("iio: accel: Support Kionix/ROHM KX022A accelerometer")
Tested-by: Jagath Jog J <jagathjog1996@gmail.com>
Link: https://lore.kernel.org/r/ZTEt7NqfDHPOkm8j@dc78bmyyyyyyyyyyyyydt-3.rev.dnainternet.fi
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/accel/kionix-kx022a.c