thermal/debugfs: Avoid printing zero duration for mitigation events in progress
If a thermal mitigation event is in progress, its duration value has
not been updated yet, so 0 will be printed as the event duration by
tze_seq_show() which is confusing.
Avoid doing that by marking the beginning of the event with the
KTIME_MIN duration value and making tze_seq_show() compute the current
event duration on the fly, in which case '>' will be printed instead of
'=' in the event duration value field.
Similarly, for trip points that have been crossed on the down, mark
the end of mitigation with the KTIME_MAX timestamp value and make
tze_seq_show() compute the current duration on the fly for the trip
points still involved in the mitigation, in which cases the duration
value printed by it will be prepended with a '>' character.
Fixes: 7ef01f228c9f ("thermal/debugfs: Add thermal debugfs information for mitigation episodes")
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
Tested-by: Lukasz Luba <lukasz.luba@arm.com>