thermal: rcar_gen3_thermal: Update calculation formula due to HW evaluation
authorHien Dang <hien.dang.eb@renesas.com>
Tue, 17 Apr 2018 20:57:46 +0000 (22:57 +0200)
committerEduardo Valentin <edubezval@gmail.com>
Sun, 6 May 2018 22:53:42 +0000 (15:53 -0700)
commitfc66ddff3840232ed102250551d7b6031a49ff17
treead5f8d5e264fad38aed13f0156759aac1a052a33
parent34283724475699f261983afdfe72dcec0ae3096a
thermal: rcar_gen3_thermal: Update calculation formula due to HW evaluation

Due to hardware evaluation result,
Max temperature is changed from 96 to 116 degree Celsius.
Also, calculation formula and pseudo FUSE values are changed accordingly.

Signed-off-by: Dien Pham <dien.pham.ry@renesas.com>
Signed-off-by: Hien Dang <hien.dang.eb@renesas.com>
Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se>
Reviewed-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
drivers/thermal/rcar_gen3_thermal.c