net: axienet: reset core on initialization prior to MDIO access
authorRobert Hancock <robert.hancock@calian.com>
Tue, 18 Jan 2022 21:41:26 +0000 (15:41 -0600)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 27 Jan 2022 10:05:32 +0000 (11:05 +0100)
commit 04cc2da39698efd7eb2e30c112538922d26f848e upstream.

In some cases where the Xilinx Ethernet core was used in 1000Base-X or
SGMII modes, which use the internal PCS/PMA PHY, and the MGT
transceiver clock source for the PCS was not running at the time the
FPGA logic was loaded, the core would come up in a state where the
PCS could not be found on the MDIO bus. To fix this, the Ethernet core
(including the PCS) should be reset after enabling the clocks, prior to
attempting to access the PCS using of_mdio_find_device.

Fixes: 1a02556086fc (net: axienet: Properly handle PCS/PMA PHY for 1000BaseX mode)
Signed-off-by: Robert Hancock <robert.hancock@calian.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/ethernet/xilinx/xilinx_axienet_main.c

index aa6f42e619dc8867b42161bfe8ffbab78cb9cc7c..a8d13676a556d777b2431e0b9f8b3ca7d6189098 100644 (file)
@@ -2091,6 +2091,11 @@ static int axienet_probe(struct platform_device *pdev)
        lp->coalesce_count_rx = XAXIDMA_DFT_RX_THRESHOLD;
        lp->coalesce_count_tx = XAXIDMA_DFT_TX_THRESHOLD;
 
+       /* Reset core now that clocks are enabled, prior to accessing MDIO */
+       ret = __axienet_device_reset(lp);
+       if (ret)
+               goto cleanup_clk;
+
        lp->phy_node = of_parse_phandle(pdev->dev.of_node, "phy-handle", 0);
        if (lp->phy_node) {
                ret = axienet_mdio_setup(lp);