Spec says, when CUR_TEMP_TJ_SEL == 3 and CUR_TEMP_RANGE_SEL == 0,
it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. The
CUR_TEMP register is read-write when CUR_TEMP_TJ_SEL == 3 (bit 17-16).
Add the check to detect it.
Sensors command's output before the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapter
Tctl: +76.6°C <- Wrong value
Tccd1: +26.5°C
Tccd2: +27.5°C
Tccd3: +27.2°C
Tccd4: +27.5°C
Tccd5: +26.0°C
Tccd6: +26.2°C
Tccd7: +25.0°C
Tccd8: +26.5°C
Sensors command's output after the patch.
$sensors
k10temp-pci-00c3
Adapter: PCI adapter
Tctl: +28.8°C <- corrected value
Tccd1: +27.5°C
Tccd2: +28.5°C
Tccd3: +28.5°C
Tccd4: +28.5°C
Tccd5: +27.0°C
Tccd6: +27.5°C
Tccd7: +27.0°C
Tccd8: +27.5°C
Signed-off-by: Babu Moger <babu.moger@amd.com>
Fixes: 1b59788979ac ("hwmon: (k10temp) Add temperature offset for Ryzen 2700X")
Link: https://lore.kernel.org/r/20230413213958.847634-1-babu.moger@amd.com
Cc: stable@vger.kernel.org
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
#define ZEN_CUR_TEMP_SHIFT 21
#define ZEN_CUR_TEMP_RANGE_SEL_MASK BIT(19)
+#define ZEN_CUR_TEMP_TJ_SEL_MASK GENMASK(17, 16)
struct k10temp_data {
struct pci_dev *pdev;
data->read_tempreg(data->pdev, ®val);
temp = (regval >> ZEN_CUR_TEMP_SHIFT) * 125;
- if (regval & data->temp_adjust_mask)
+ if ((regval & data->temp_adjust_mask) ||
+ (regval & ZEN_CUR_TEMP_TJ_SEL_MASK) == ZEN_CUR_TEMP_TJ_SEL_MASK)
temp -= 49000;
return temp;
}