On SAMA7G5 final chip version there is no need for 5 degrees Celsius
adjustment when computing junction temperature, thus, remove it.
Fixes: 5ab38b81895c ("iio: adc: at91-sama5d2_adc: add support for temperature sensor")
Signed-off-by: Claudiu Beznea <claudiu.beznea@microchip.com>
Link: https://lore.kernel.org/r/20221020102705.3639204-1-claudiu.beznea@microchip.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
clb->p6 = buf[AT91_ADC_TS_CLB_IDX_P6];
/*
- * We prepare here the conversion to milli and also add constant
- * factor (5 degrees Celsius) to p1 here to avoid doing it on
- * hotpath.
+ * We prepare here the conversion to milli to avoid doing it on hotpath.
*/
- clb->p1 = clb->p1 * 1000 + 5000;
+ clb->p1 = clb->p1 * 1000;
free_buf:
kfree(buf);