<title><constant>DTV_INNER_FEC</constant></title>
        <para>Used cable/satellite transmissions. The acceptable values are:
        </para>
-       <programlisting>
-typedef enum fe_code_rate {
-       FEC_NONE = 0,
-       FEC_1_2,
-       FEC_2_3,
-       FEC_3_4,
-       FEC_4_5,
-       FEC_5_6,
-       FEC_6_7,
-       FEC_7_8,
-       FEC_8_9,
-       FEC_AUTO,
-       FEC_3_5,
-       FEC_9_10,
-       FEC_2_5,
-} fe_code_rate_t;
-       </programlisting>
-       <para>which correspond to error correction rates of 1/2, 2/3, etc.,
-       no error correction or auto detection.</para>
+<section id="fe-code-rate-t">
+<title>enum fe_code_rate: type of the Forward Error Correction.</title>
+
+<table pgwide="1" frame="none" id="fe-code-rate">
+    <title>enum fe_code_rate</title>
+    <tgroup cols="2">
+       &cs-def;
+       <thead>
+       <row>
+           <entry>ID</entry>
+           <entry>Description</entry>
+       </row>
+       </thead>
+       <tbody valign="top">
+       <row>
+           <entry>TRANSMISSION_MODE_AUTO</entry>
+           <entry>Autodetect transmission mode. The hardware will try to find
+               the correct FFT-size (if capable) to fill in the missing
+               parameters.</entry>
+       </row><row>
+           <entry>FEC_NONE</entry>
+           <entry>No Forward Error Correction Code</entry>
+       </row><row>
+           <entry>FEC_AUTO</entry>
+           <entry>Autodetect Error Correction Code</entry>
+       </row><row>
+           <entry>FEC_1_2</entry>
+           <entry>Forward Error Correction Code 1/2</entry>
+       </row><row>
+           <entry>FEC_2_3</entry>
+           <entry>Forward Error Correction Code 2/3</entry>
+       </row><row>
+           <entry>FEC_3_4</entry>
+           <entry>Forward Error Correction Code 3/4</entry>
+       </row><row>
+           <entry>FEC_4_5</entry>
+           <entry>Forward Error Correction Code 4/5</entry>
+       </row><row>
+           <entry>FEC_5_6</entry>
+           <entry>Forward Error Correction Code 5/6</entry>
+       </row><row>
+           <entry>FEC_6_7</entry>
+           <entry>Forward Error Correction Code 6/7</entry>
+       </row><row>
+           <entry>FEC_7_8</entry>
+           <entry>Forward Error Correction Code 7/8</entry>
+       </row><row>
+           <entry>FEC_8_9</entry>
+           <entry>Forward Error Correction Code 8/9</entry>
+       </row><row>
+           <entry>FEC_9_10</entry>
+           <entry>Forward Error Correction Code 9/10</entry>
+       </row><row>
+           <entry>FEC_2_5</entry>
+           <entry>Forward Error Correction Code 2/5</entry>
+       </row><row>
+           <entry>FEC_3_5</entry>
+           <entry>Forward Error Correction Code 3/5</entry>
+       </row><row>
+       </row>
+        </tbody>
+    </tgroup>
+</table>
+</section>
        </section>
        <section id="DTV-VOLTAGE">
        <title><constant>DTV_VOLTAGE</constant></title>
        </section>
        <section id="DTV-CODE-RATE-HP">
        <title><constant>DTV_CODE_RATE_HP</constant></title>
-       <para>Used on terrestrial transmissions. The acceptable values are:
+       <para>Used on terrestrial transmissions.  The acceptable values are
+           the ones described at &fe-transmit-mode-t;.
        </para>
-       <programlisting>
-typedef enum fe_code_rate {
-       FEC_NONE = 0,
-       FEC_1_2,
-       FEC_2_3,
-       FEC_3_4,
-       FEC_4_5,
-       FEC_5_6,
-       FEC_6_7,
-       FEC_7_8,
-       FEC_8_9,
-       FEC_AUTO,
-       FEC_3_5,
-       FEC_9_10,
-} fe_code_rate_t;
-       </programlisting>
        </section>
        <section id="DTV-CODE-RATE-LP">
        <title><constant>DTV_CODE_RATE_LP</constant></title>
-       <para>Used on terrestrial transmissions. The acceptable values are:
+       <para>Used on terrestrial transmissions. The acceptable values are
+           the ones described at &fe-transmit-mode-t;.
        </para>
-       <programlisting>
-typedef enum fe_code_rate {
-       FEC_NONE = 0,
-       FEC_1_2,
-       FEC_2_3,
-       FEC_3_4,
-       FEC_4_5,
-       FEC_5_6,
-       FEC_6_7,
-       FEC_7_8,
-       FEC_8_9,
-       FEC_AUTO,
-       FEC_3_5,
-       FEC_9_10,
-} fe_code_rate_t;
-       </programlisting>
+
        </section>
+
        <section id="DTV-GUARD-INTERVAL">
                <title><constant>DTV_GUARD_INTERVAL</constant></title>
 
 
 
 &sub-dvbproperty;
 
-<section id="fe-code-rate-t">
-<title>frontend code rate</title>
-<para>The possible values for the <constant>fec_inner</constant> field used on
-<link linkend="dvb-qpsk-parameters"><constant>struct dvb_qpsk_parameters</constant></link> and
-<link linkend="dvb-qam-parameters"><constant>struct dvb_qam_parameters</constant></link> are:
-</para>
-<programlisting>
-typedef enum fe_code_rate {
-       FEC_NONE = 0,
-       FEC_1_2,
-       FEC_2_3,
-       FEC_3_4,
-       FEC_4_5,
-       FEC_5_6,
-       FEC_6_7,
-       FEC_7_8,
-       FEC_8_9,
-       FEC_AUTO,
-       FEC_3_5,
-       FEC_9_10,
-} fe_code_rate_t;
-</programlisting>
-<para>which correspond to error correction rates of 1/2, 2/3, etc., no error correction or auto
-detection.
-</para>
-</section>
-
-
 <section>
 <title>More OFDM parameters</title>
 
 
 <programlisting>
  struct dvb_qpsk_parameters {
         uint32_t        symbol_rate;  /⋆ symbol rate in Symbols per second ⋆/
-        fe_code_rate_t  fec_inner;    /⋆ forward error correction (see above) ⋆/
+        &fe-code-rate-t;  fec_inner;    /⋆ forward error correction (see above) ⋆/
  };
 </programlisting>
 </section>
 <programlisting>
  struct dvb_qam_parameters {
         uint32_t         symbol_rate; /⋆ symbol rate in Symbols per second ⋆/
-        fe_code_rate_t   fec_inner;   /⋆ forward error correction (see above) ⋆/
+        &fe-code-rate-t;   fec_inner;   /⋆ forward error correction (see above) ⋆/
         &fe-modulation-t;  modulation;  /⋆ modulation type (see above) ⋆/
  };
 </programlisting>
 <programlisting>
  struct dvb_ofdm_parameters {
         &fe-bandwidth-t;      bandwidth;
-        fe_code_rate_t      code_rate_HP;  /⋆ high priority stream code rate ⋆/
-        fe_code_rate_t      code_rate_LP;  /⋆ low priority stream code rate ⋆/
+        &fe-code-rate-t;      code_rate_HP;  /⋆ high priority stream code rate ⋆/
+        &fe-code-rate-t;      code_rate_LP;  /⋆ low priority stream code rate ⋆/
         &fe-modulation-t;     constellation; /⋆ modulation type (see above) ⋆/
         &fe-transmit-mode-t;  transmission_mode;
         fe_guard_interval_t guard_interval;