ACPI battery interface reports its state either in mW or in mA, and
discharge rate in your case is reported in mW. power_supply interface
does not have such a parameter, so current_now parameter is used
for all cases. But in case of mW, reported discharge should
be converted into mA.
Signed-off-by: Alexey Starikovskiy <astarikovskiy@suse.de>
Tested-by: Ferenc Wagner <wferi@niif.hu>
Signed-off-by: Len Brown <len.brown@intel.com>
                break;
        case POWER_SUPPLY_PROP_CURRENT_NOW:
                val->intval = battery->current_now * 1000;
+               /* if power units are mW, convert to mA by
+                  dividing by current voltage (mV/1000) */
+               if (!battery->power_unit) {
+                       if (battery->voltage_now) {
+                               val->intval /= battery->voltage_now;
+                               val->intval *= 1000;
+                       } else
+                               val->intval = -1;
+               }
                break;
        case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
        case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN: