The X/Y position measurements read from the controller are interpreted
wrong. The first measurement X+ contains the Y position, and the second
measurement Y+ the X position (see also Table 11 Register Table in the
data sheet).
The problem is already known and a swap option has been introduced:
commit 
6680884a4420 ("Input: ad7879 - add option to correct xy axis")
However, the meaning of the new boolean is inverted since the underlying
values are already swapped. Let ts->swap_xy set to true actually be the
swapped configuration of the two axis.
Signed-off-by: Stefan Agner <stefan@agner.ch>
Acked-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
 
 #define AD7879_TEMP_BIT                        (1<<1)
 
 enum {
-       AD7879_SEQ_XPOS  = 0,
-       AD7879_SEQ_YPOS  = 1,
+       AD7879_SEQ_YPOS  = 0,
+       AD7879_SEQ_XPOS  = 1,
        AD7879_SEQ_Z1    = 2,
        AD7879_SEQ_Z2    = 3,
        AD7879_NR_SENSE  = 4,
        ts->dev = dev;
        ts->input = input_dev;
        ts->irq = irq;
-       ts->swap_xy = pdata->swap_xy;
+
+       /* Use swapped axis by default (backward compatibility) */
+       ts->swap_xy = !pdata->swap_xy;
 
        setup_timer(&ts->timer, ad7879_timer, (unsigned long) ts);