The following warning is observed on the Jetson TX2 platform ...

 WARNING KERN tegra-sor 15540000.sor: 15540000.sor supply \
              vdd-hdmi-dp-pll not found, using dummy regulator

The problem is caused because the regulator for the SOR device is
missing the '-supply' suffix in Device-Tree. Therefore, add the
'-supply' suffix to fix this warning.

Fixes: 3fdfaf8718fa ("arm64: tegra: Enable DP support on Jetson TX2")
Signed-off-by: Jon Hunter <jonathanh@nvidia.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>
arch/arm64/boot/dts/nvidia/tegra186-p2771-0000.dts

index 961b1be0c56b63f4f904d9965512651f1b225243..1af7f9ffb7b6083bda9aa9a98c39399be8a059d7 100644 (file)
                        status = "okay";
 
                        avdd-io-hdmi-dp-supply = <&vdd_hdmi_1v05>;
-                       vdd-hdmi-dp-pll = <&vdd_1v8_ap>;
+                       vdd-hdmi-dp-pll-supply = <&vdd_1v8_ap>;
 
                        nvidia,dpaux = <&dpaux>;
                };