hw/nvme: namespace parameter for EUI-64
authorHeinrich Schuchardt <xypron.glpk@gmx.de>
Mon, 14 Jun 2021 20:19:00 +0000 (22:19 +0200)
committerKlaus Jensen <k.jensen@samsung.com>
Tue, 29 Jun 2021 05:16:25 +0000 (07:16 +0200)
The EUI-64 field is the only identifier for NVMe namespaces in UEFI device
paths. Add a new namespace property "eui64", that provides the user the
option to specify the EUI-64.

Signed-off-by: Heinrich Schuchardt <xypron.glpk@gmx.de>
Acked-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
docs/system/nvme.rst
hw/nvme/ctrl.c
hw/nvme/ns.c
hw/nvme/nvme.h

index f7f63d6bf6153bf83a3530b1d08d8a4913aba158..b5f8288d7c854434cd2e162f48100f35b49fd225 100644 (file)
@@ -81,6 +81,10 @@ There are a number of parameters available:
   Set the UUID of the namespace. This will be reported as a "Namespace UUID"
   descriptor in the Namespace Identification Descriptor List.
 
+``eui64``
+  Set the EUI-64 of the namespace. This will be reported as a "IEEE Extended
+  Unique Identifier" descriptor in the Namespace Identification Descriptor List.
+
 ``bus``
   If there are more ``nvme`` devices defined, this parameter may be used to
   attach the namespace to a specific ``nvme`` device (identified by an ``id``
index 7dea64b72e6a908ab077d6ea130663b319f25e9f..762bb82e3cacb82ea87947d968696a1be427228a 100644 (file)
@@ -4426,19 +4426,19 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
     NvmeIdentify *c = (NvmeIdentify *)&req->cmd;
     uint32_t nsid = le32_to_cpu(c->nsid);
     uint8_t list[NVME_IDENTIFY_DATA_SIZE] = {};
-
-    struct data {
-        struct {
-            NvmeIdNsDescr hdr;
-            uint8_t v[NVME_NIDL_UUID];
-        } uuid;
-        struct {
-            NvmeIdNsDescr hdr;
-            uint8_t v;
-        } csi;
-    };
-
-    struct data *ns_descrs = (struct data *)list;
+    uint8_t *pos = list;
+    struct {
+        NvmeIdNsDescr hdr;
+        uint8_t v[NVME_NIDL_UUID];
+    } QEMU_PACKED uuid;
+    struct {
+        NvmeIdNsDescr hdr;
+        uint64_t v;
+    } QEMU_PACKED eui64;
+    struct {
+        NvmeIdNsDescr hdr;
+        uint8_t v;
+    } QEMU_PACKED csi;
 
     trace_pci_nvme_identify_ns_descr_list(nsid);
 
@@ -4452,17 +4452,29 @@ static uint16_t nvme_identify_ns_descr_list(NvmeCtrl *n, NvmeRequest *req)
     }
 
     /*
-     * Because the NGUID and EUI64 fields are 0 in the Identify Namespace data
-     * structure, a Namespace UUID (nidt = 3h) must be reported in the
-     * Namespace Identification Descriptor. Add the namespace UUID here.
+     * If the EUI-64 field is 0 and the NGUID field is 0, the namespace must
+     * provide a valid Namespace UUID in the Namespace Identification Descriptor
+     * data structure. QEMU does not yet support setting NGUID.
      */
-    ns_descrs->uuid.hdr.nidt = NVME_NIDT_UUID;
-    ns_descrs->uuid.hdr.nidl = NVME_NIDL_UUID;
-    memcpy(&ns_descrs->uuid.v, ns->params.uuid.data, NVME_NIDL_UUID);
-
-    ns_descrs->csi.hdr.nidt = NVME_NIDT_CSI;
-    ns_descrs->csi.hdr.nidl = NVME_NIDL_CSI;
-    ns_descrs->csi.v = ns->csi;
+    uuid.hdr.nidt = NVME_NIDT_UUID;
+    uuid.hdr.nidl = NVME_NIDL_UUID;
+    memcpy(uuid.v, ns->params.uuid.data, NVME_NIDL_UUID);
+    memcpy(pos, &uuid, sizeof(uuid));
+    pos += sizeof(uuid);
+
+    if (ns->params.eui64) {
+        eui64.hdr.nidt = NVME_NIDT_EUI64;
+        eui64.hdr.nidl = NVME_NIDL_EUI64;
+        eui64.v = cpu_to_be64(ns->params.eui64);
+        memcpy(pos, &eui64, sizeof(eui64));
+        pos += sizeof(eui64);
+    }
+
+    csi.hdr.nidt = NVME_NIDT_CSI;
+    csi.hdr.nidl = NVME_NIDL_CSI;
+    csi.v = ns->csi;
+    memcpy(pos, &csi, sizeof(csi));
+    pos += sizeof(csi);
 
     return nvme_c2h(n, list, sizeof(list), req);
 }
index 3fec9c627321b0eaf5874aa61f5ae41205933951..45e457de6ae18a201cb9600389d336a59fc8777d 100644 (file)
@@ -77,6 +77,7 @@ static int nvme_ns_init(NvmeNamespace *ns, Error **errp)
     id_ns->mssrl = cpu_to_le16(ns->params.mssrl);
     id_ns->mcl = cpu_to_le32(ns->params.mcl);
     id_ns->msrc = ns->params.msrc;
+    id_ns->eui64 = cpu_to_be64(ns->params.eui64);
 
     ds = 31 - clz32(ns->blkconf.logical_block_size);
     ms = ns->params.ms;
@@ -511,6 +512,7 @@ static Property nvme_ns_props[] = {
     DEFINE_PROP_BOOL("shared", NvmeNamespace, params.shared, false),
     DEFINE_PROP_UINT32("nsid", NvmeNamespace, params.nsid, 0),
     DEFINE_PROP_UUID("uuid", NvmeNamespace, params.uuid),
+    DEFINE_PROP_UINT64("eui64", NvmeNamespace, params.eui64, 0),
     DEFINE_PROP_UINT16("ms", NvmeNamespace, params.ms, 0),
     DEFINE_PROP_UINT8("mset", NvmeNamespace, params.mset, 0),
     DEFINE_PROP_UINT8("pi", NvmeNamespace, params.pi, 0),
index 93a7e0e5380e63dac162a83ba316811835a8814f..ac90e13d7b3fc4b1bf919896e0fc1691bfb304c8 100644 (file)
@@ -83,6 +83,7 @@ typedef struct NvmeNamespaceParams {
     bool     shared;
     uint32_t nsid;
     QemuUUID uuid;
+    uint64_t eui64;
 
     uint16_t ms;
     uint8_t  mset;