When running seL4 tests (https://docs.sel4.systems/projects/sel4test)
on the sabrelight platform, the timer tests fail. The arm/imx6 EPIT
timer interrupt does not fire properly, instead of a e.g. second in
can take up to a minute to finally see the interrupt.
Resolves: https://gitlab.com/qemu-project/qemu/-/issues/1263
Signed-off-by: Axel Heider <axel.heider@hensoldt.net>
Message-id:
166663118138.13362.
1229967229046092876-0@git.sr.ht
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
/* If IOVW bit is set then set the timer value */
ptimer_set_count(s->timer_reload, s->lr);
}
-
+ /*
+ * Commit the change to s->timer_reload, so it can propagate. Otherwise
+ * the timer interrupt may not fire properly. The commit must happen
+ * before calling imx_epit_reload_compare_timer(), which reads
+ * s->timer_reload internally again.
+ */
+ ptimer_transaction_commit(s->timer_reload);
imx_epit_reload_compare_timer(s);
ptimer_transaction_commit(s->timer_cmp);
- ptimer_transaction_commit(s->timer_reload);
break;
case 3: /* CMP */