mos6522: only clear the shift register interrupt upon write
authorMark Cave-Ayland <mark.cave-ayland@ilande.co.uk>
Wed, 13 Jun 2018 08:30:13 +0000 (09:30 +0100)
committerDavid Gibson <david@gibson.dropbear.id.au>
Sat, 16 Jun 2018 06:32:33 +0000 (16:32 +1000)
According to the 6522 datasheet the shift register (SR) interrupt flag is
cleared upon write with no mention of any other interrupt flags.

Signed-off-by: Mark Cave-Ayland <mark.cave-ayland@ilande.co.uk>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
hw/misc/mos6522.c

index 44eb306cf1d3f34aee59c4122b10680cda79b96a..ad5041d8c041d2e18a2f6031b88d27d0f954a974 100644 (file)
@@ -241,7 +241,7 @@ uint64_t mos6522_read(void *opaque, hwaddr addr, unsigned size)
         break;
     case VIA_REG_SR:
         val = s->sr;
-        s->ifr &= ~(SR_INT | CB1_INT | CB2_INT);
+        s->ifr &= ~SR_INT;
         mos6522_update_irq(s);
         break;