RAVB doesn't need mdiobus suspend/resume, that's why it sets
'mac_managed_pm'. However, setting it needs to be moved from init to
probe, so mdiobus PM functions will really never be called (e.g. when
the interface is not up yet during suspend/resume).
Fixes: 4924c0cdce75 ("net: ravb: Fix PHY state warning splat during system resume")
Suggested-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Reviewed-by: Michal Kubiak <michal.kubiak@intel.com>
Reviewed-by: Sergey Shtylyov <s.shtylyov@omp.ru>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
phy_remove_link_mode(phydev, ETHTOOL_LINK_MODE_100baseT_Half_BIT);
}
- /* Indicate that the MAC is responsible for managing PHY PM */
- phydev->mac_managed_pm = true;
phy_attached_info(phydev);
return 0;
{
struct platform_device *pdev = priv->pdev;
struct device *dev = &pdev->dev;
+ struct phy_device *phydev;
+ struct device_node *pn;
int error;
/* Bitbang init */
if (error)
goto out_free_bus;
+ pn = of_parse_phandle(dev->of_node, "phy-handle", 0);
+ phydev = of_phy_find_device(pn);
+ if (phydev) {
+ phydev->mac_managed_pm = true;
+ put_device(&phydev->mdio.dev);
+ }
+ of_node_put(pn);
+
return 0;
out_free_bus: