The MAX9271 GPIO1 line that controls the sensor reset is by default
enabled after a serializer chip reset.
As rdacm20 does not go through an explicit serializer reset, make sure
GPIO1 is enabled to make the camera module driver more robust.
Fixes: 34009bffc1c6 ("media: i2c: Add RDACM20 driver")
Signed-off-by: Jacopo Mondi <jacopo+renesas@jmondi.org>
Reviewed-by: Kieran Bingham <kieran.bingham+renesas@ideasonboard.com>
Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
         * Reset the sensor by cycling the OV10635 reset signal connected to the
         * MAX9271 GPIO1 and verify communication with the OV10635.
         */
-       max9271_clear_gpios(dev->serializer, MAX9271_GPIO1OUT);
+       ret = max9271_enable_gpios(dev->serializer, MAX9271_GPIO1OUT);
+       if (ret)
+               return ret;
+
+       ret = max9271_clear_gpios(dev->serializer, MAX9271_GPIO1OUT);
+       if (ret)
+               return ret;
        usleep_range(10000, 15000);
-       max9271_set_gpios(dev->serializer, MAX9271_GPIO1OUT);
+
+       ret = max9271_set_gpios(dev->serializer, MAX9271_GPIO1OUT);
+       if (ret)
+               return ret;
        usleep_range(10000, 15000);
 
 again: