Since the PWM framework is switching struct pwm_state.duty_cycle's
datatype to u64, prepare for this transition by using DIV_ROUND_UP_ULL
to handle a 64-bit dividend.
Signed-off-by: Guru Das Srinagesh <gurus@codeaurora.org>
Reviewed-by: Jani Nikula <jani.nikula@intel.com>
Acked-by: Jani Nikula <jani.nikula@intel.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
return retval;
}
- level = DIV_ROUND_UP(pwm_get_duty_cycle(panel->backlight.pwm) * 100,
+ level = DIV_ROUND_UP_ULL(pwm_get_duty_cycle(panel->backlight.pwm) * 100,
CRC_PMIC_PWM_PERIOD_NS);
panel->backlight.level =
intel_panel_compute_brightness(connector, level);