dp_retrain_link_dp_test(link, &link_settings, false);
 }
 
-/* TODO hbr2 compliance eye output is unstable
+/* TODO Raven hbr2 compliance eye output is unstable
  * (toggling on and off) with debugger break
  * This caueses intermittent PHY automation failure
  * Need to look into the root cause */
-static uint8_t force_tps4_for_cp2520 = 1;
-
 static void dp_test_send_phy_test_pattern(struct dc_link *link)
 {
        union phy_test_pattern dpcd_test_pattern;
                break;
        case PHY_TEST_PATTERN_CP2520_1:
                /* CP2520 pattern is unstable, temporarily use TPS4 instead */
-               test_pattern = (force_tps4_for_cp2520 == 1) ?
+               test_pattern = (link->dc->caps.force_dp_tps4_for_cp2520 == 1) ?
                                DP_TEST_PATTERN_TRAINING_PATTERN4 :
                                DP_TEST_PATTERN_HBR2_COMPLIANCE_EYE;
                break;
        case PHY_TEST_PATTERN_CP2520_2:
                /* CP2520 pattern is unstable, temporarily use TPS4 instead */
-               test_pattern = (force_tps4_for_cp2520 == 1) ?
+               test_pattern = (link->dc->caps.force_dp_tps4_for_cp2520 == 1) ?
                                DP_TEST_PATTERN_TRAINING_PATTERN4 :
                                DP_TEST_PATTERN_HBR2_COMPLIANCE_EYE;
                break;
 
        dc->caps.max_slave_planes = 1;
        dc->caps.is_apu = true;
        dc->caps.post_blend_color_processing = false;
+       /* Raven DP PHY HBR2 eye diagram pattern is not stable. Use TP4 */
+       dc->caps.force_dp_tps4_for_cp2520 = true;
 
        if (dc->ctx->dce_environment == DCE_ENV_PRODUCTION_DRV)
                dc->debug = debug_defaults_drv;