We shouldn't receive characters when the full UART or its
receiver is disabled. However we don't want to break the
possibly incomplete "my first bare metal assembly program"s,
so we choose to simply display a warning when this occurs.
Reviewed-by: Richard Henderson <richard.henderson@linaro.org>
Signed-off-by: Philippe Mathieu-Daudé <philmd@linaro.org>
Reviewed-by: Luc Michel <luc.michel@amd.com>
Message-Id: <
20250220092903.3726-2-philmd@linaro.org>
#define CR_OUT1 (1 << 12)
#define CR_RTS (1 << 11)
#define CR_DTR (1 << 10)
+#define CR_RXE (1 << 9)
#define CR_TXE (1 << 8)
#define CR_LBE (1 << 7)
#define CR_UARTEN (1 << 0)
PL011State *s = (PL011State *)opaque;
int r;
+ if (!(s->cr & CR_UARTEN)) {
+ qemu_log_mask(LOG_GUEST_ERROR,
+ "PL011 receiving data on disabled UART\n");
+ }
+ if (!(s->cr & CR_RXE)) {
+ qemu_log_mask(LOG_GUEST_ERROR,
+ "PL011 receiving data on disabled RX UART\n");
+ }
r = s->read_count < pl011_get_fifo_depth(s);
trace_pl011_can_receive(s->lcr, s->read_count, r);
return r;