will be called aht10.
 
 config SENSORS_AQUACOMPUTER_D5NEXT
-       tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, and Farbwerk 360"
+       tristate "Aquacomputer D5 Next, Octo, Quadro, Farbwerk, Farbwerk 360, High Flow Next"
        depends on USB_HID
        select CRC16
        help
          If you say yes here you get support for sensors and fans of
          the Aquacomputer D5 Next watercooling pump, Octo and Quadro fan
-         controllers, Farbwerk and Farbwerk 360 RGB controllers, where
-         available.
+         controllers, Farbwerk and Farbwerk 360 RGB controllers, High Flow
+         Next sensor, where available.
 
          This driver can also be built as a module. If so, the module
          will be called aquacomputer_d5next.
 
 // SPDX-License-Identifier: GPL-2.0+
 /*
  * hwmon driver for Aquacomputer devices (D5 Next, Farbwerk, Farbwerk 360, Octo,
- * Quadro)
+ * Quadro, High Flow Next)
  *
  * Aquacomputer devices send HID reports (with ID 0x01) every second to report
  * sensor values.
 #define USB_PRODUCT_ID_D5NEXT          0xf00e
 #define USB_PRODUCT_ID_FARBWERK360     0xf010
 #define USB_PRODUCT_ID_OCTO            0xf011
+#define USB_PRODUCT_ID_HIGHFLOWNEXT    0xf012
 
-enum kinds { d5next, farbwerk, farbwerk360, octo, quadro };
+enum kinds { d5next, farbwerk, farbwerk360, octo, quadro, highflownext };
 
 static const char *const aqc_device_names[] = {
        [d5next] = "d5next",
        [farbwerk] = "farbwerk",
        [farbwerk360] = "farbwerk360",
        [octo] = "octo",
-       [quadro] = "quadro"
+       [quadro] = "quadro",
+       [highflownext] = "highflownext"
 };
 
 #define DRIVER_NAME                    "aquacomputer_d5next"
 /* Fan speed registers in Quadro control report (from 0-100%) */
 static u16 quadro_ctrl_fan_offsets[] = { 0x37, 0x8c, 0xe1, 0x136 };
 
+/* Register offsets for the High Flow Next */
+#define HIGHFLOWNEXT_NUM_SENSORS       2
+#define HIGHFLOWNEXT_SENSOR_START      85
+#define HIGHFLOWNEXT_FLOW              81
+#define HIGHFLOWNEXT_WATER_QUALITY     89
+#define HIGHFLOWNEXT_POWER             91
+#define HIGHFLOWNEXT_CONDUCTIVITY      95
+#define HIGHFLOWNEXT_5V_VOLTAGE                97
+#define HIGHFLOWNEXT_5V_VOLTAGE_USB    99
+
 /* Labels for D5 Next */
 static const char *const label_d5next_temp[] = {
        "Coolant temp"
        "Flow speed [dL/h]"
 };
 
+/* Labels for High Flow Next */
+static const char *const label_highflownext_temp_sensors[] = {
+       "Coolant temp",
+       "External sensor"
+};
+
+static const char *const label_highflownext_fan_speed[] = {
+       "Flow [dL/h]",
+       "Water quality [%]",
+       "Conductivity [nS/cm]",
+};
+
+static const char *const label_highflownext_power[] = {
+       "Dissipated power",
+};
+
+static const char *const label_highflownext_voltage[] = {
+       "+5V voltage",
+       "+5V USB voltage"
+};
+
 struct aqc_data {
        struct hid_device *hdev;
        struct device *hwmon_dev;
                break;
        case hwmon_fan:
                switch (priv->kind) {
+               case highflownext:
+                       /* Special case to support flow sensor, water quality and conductivity */
+                       if (channel < 3)
+                               return 0444;
+                       break;
                case quadro:
                        /* Special case to support flow sensor */
                        if (channel < priv->num_fans + 1)
                }
                break;
        case hwmon_power:
+               switch (priv->kind) {
+               case highflownext:
+                       /* Special case to support one power sensor */
+                       if (channel == 0)
+                               return 0444;
+                       break;
+               default:
+                       if (channel < priv->num_fans)
+                               return 0444;
+                       break;
+               }
+               break;
        case hwmon_curr:
                if (channel < priv->num_fans)
                        return 0444;
                        if (channel < priv->num_fans + 2)
                                return 0444;
                        break;
+               case highflownext:
+                       /* Special case to support two voltage sensors */
+                       if (channel < 2)
+                               return 0444;
+                       break;
                default:
                        if (channel < priv->num_fans)
                                return 0444;
        case quadro:
                priv->speed_input[4] = get_unaligned_be16(data + priv->flow_sensor_offset);
                break;
+       case highflownext:
+               /* If external temp sensor is not connected, its power reading is also N/A */
+               if (priv->temp_input[1] == -ENODATA)
+                       priv->power_input[0] = -ENODATA;
+               else
+                       priv->power_input[0] =
+                           get_unaligned_be16(data + HIGHFLOWNEXT_POWER) * 1000000;
+
+               priv->voltage_input[0] = get_unaligned_be16(data + HIGHFLOWNEXT_5V_VOLTAGE) * 10;
+               priv->voltage_input[1] =
+                   get_unaligned_be16(data + HIGHFLOWNEXT_5V_VOLTAGE_USB) * 10;
+
+               priv->speed_input[0] = get_unaligned_be16(data + HIGHFLOWNEXT_FLOW);
+               priv->speed_input[1] = get_unaligned_be16(data + HIGHFLOWNEXT_WATER_QUALITY);
+               priv->speed_input[2] = get_unaligned_be16(data + HIGHFLOWNEXT_CONDUCTIVITY);
+               break;
        default:
                break;
        }
                priv->voltage_label = label_fan_voltage;
                priv->current_label = label_fan_current;
                break;
+       case USB_PRODUCT_ID_HIGHFLOWNEXT:
+               priv->kind = highflownext;
+
+               priv->num_fans = 0;
+               priv->num_temp_sensors = HIGHFLOWNEXT_NUM_SENSORS;
+               priv->temp_sensor_start_offset = HIGHFLOWNEXT_SENSOR_START;
+               priv->power_cycle_count_offset = QUADRO_POWER_CYCLES;
+
+               priv->temp_label = label_highflownext_temp_sensors;
+               priv->speed_label = label_highflownext_fan_speed;
+               priv->power_label = label_highflownext_power;
+               priv->voltage_label = label_highflownext_voltage;
+               break;
        default:
                break;
        }
        { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_FARBWERK360) },
        { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_OCTO) },
        { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_QUADRO) },
+       { HID_USB_DEVICE(USB_VENDOR_ID_AQUACOMPUTER, USB_PRODUCT_ID_HIGHFLOWNEXT) },
        { }
 };