ARM: PL061: Clear PL061 device state after reset
authorWei Huang <wei@redhat.com>
Thu, 18 Feb 2016 14:16:17 +0000 (14:16 +0000)
committerPeter Maydell <peter.maydell@linaro.org>
Thu, 18 Feb 2016 14:26:33 +0000 (14:26 +0000)
Current QEMU doesn't clear PL061 state after reset. This causes a
weird issue with guest reboot via GPIO. Here is the device state
with two reboot requests:

  (PL061State fields)           data   old_in_data   istate
VM boot                         0      0             0
After 1st ACPI reboot request   8      8             8
After VM PL061 driver ACK       8      8             0
After VM reboot                 8      8             0
------------------------------------------------------------
2nd ACPI reboot request         8

In the second reboot request above, because the old_in_data field is 8,
QEMU decides that there is a pending edge IRQ already (see
pl061_update()) in input; so it doesn't raise up IRQ again. As a result
the second reboot request is lost. The correct way is to clear PL061
device state after reset.

The default reset state is found from the documents listed below. Per
Peter's suggestion that QEMU automatically calls reset function after
device initialization, this patch removes calling pl061_reset() from
pl061_initfn().

Reference:
[1] PL061 Technical Reference Manual
[2] Stellaris LM3S8962 Microcontroller Data Sheet
[3] Stellaris LM3S5P31 Microcontroller Data Sheet

Signed-off-by: Wei Huang <wei@redhat.com>
Message-id: 1455729552-28026-2-git-send-email-wei@redhat.com
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
hw/gpio/pl061.c

index e5a696ef435f9e0523ca8acbd60dc330f8a6e8b6..f9773b8a43a6a0b02b1c13a77a31084dab75b7c7 100644 (file)
@@ -282,10 +282,32 @@ static void pl061_write(void *opaque, hwaddr offset,
     pl061_update(s);
 }
 
-static void pl061_reset(PL061State *s)
+static void pl061_reset(DeviceState *dev)
 {
-  s->locked = 1;
-  s->cr = 0xff;
+    PL061State *s = PL061(dev);
+
+    /* reset values from PL061 TRM, Stellaris LM3S5P31 & LM3S8962 Data Sheet */
+    s->data = 0;
+    s->old_out_data = 0;
+    s->old_in_data = 0;
+    s->dir = 0;
+    s->isense = 0;
+    s->ibe = 0;
+    s->iev = 0;
+    s->im = 0;
+    s->istate = 0;
+    s->afsel = 0;
+    s->dr2r = 0xff;
+    s->dr4r = 0;
+    s->dr8r = 0;
+    s->odr = 0;
+    s->pur = 0;
+    s->pdr = 0;
+    s->slr = 0;
+    s->den = 0;
+    s->locked = 1;
+    s->cr = 0xff;
+    s->amsel = 0;
 }
 
 static void pl061_set_irq(void * opaque, int irq, int level)
@@ -318,7 +340,7 @@ static int pl061_initfn(SysBusDevice *sbd)
     sysbus_init_irq(sbd, &s->irq);
     qdev_init_gpio_in(dev, pl061_set_irq, 8);
     qdev_init_gpio_out(dev, s->out, 8);
-    pl061_reset(s);
+
     return 0;
 }
 
@@ -343,6 +365,7 @@ static void pl061_class_init(ObjectClass *klass, void *data)
 
     k->init = pl061_initfn;
     dc->vmsd = &vmstate_pl061;
+    dc->reset = &pl061_reset;
 }
 
 static const TypeInfo pl061_info = {