The amplifier doesn't loose register state in software shutdown mode, so
there is no need to reset the cur_* values.
Without these resets, the amplifier can be turned on after
runtime_suspend without waiting for the program and
profile to be restored.
Fixes: 5be27f1e3ec9 ("ALSA: hda/tas2781: Add tas2781 HDA driver")
Signed-off-by: Gergo Koteles <soyer@irl.hu>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
Message-ID: <
aa27ae084150988bf6a0ead7e3403bc485d790f8.
1709918447.git.soyer@irl.hu>
static int tas2781_runtime_suspend(struct device *dev)
{
struct tas2781_hda *tas_hda = dev_get_drvdata(dev);
- int i;
dev_dbg(tas_hda->dev, "Runtime Suspend\n");
tas_hda->priv->playback_started = false;
}
- for (i = 0; i < tas_hda->priv->ndev; i++) {
- tas_hda->priv->tasdevice[i].cur_book = -1;
- tas_hda->priv->tasdevice[i].cur_prog = -1;
- tas_hda->priv->tasdevice[i].cur_conf = -1;
- }
-
mutex_unlock(&tas_hda->priv->codec_lock);
return 0;