Several block device properties related to blocksize configuration must
be in certain relationship WRT each other: physical block must be no
smaller than logical block; min_io_size, opt_io_size, and
discard_granularity must be a multiple of a logical block.
To ensure these requirements are met, add corresponding consistency
checks to blkconf_blocksizes, adjusting its signature to communicate
possible error to the caller. Also remove the now redundant consistency
checks from the specific devices.
Signed-off-by: Roman Kagan <rvkagan@yandex-team.ru>
Reviewed-by: Eric Blake <eblake@redhat.com>
Reviewed-by: Paul Durrant <paul@xen.org>
Message-Id: <
20200528225516.
1676602-3-rvkagan@yandex-team.ru>
Signed-off-by: Kevin Wolf <kwolf@redhat.com>
return true;
}
-void blkconf_blocksizes(BlockConf *conf)
+bool blkconf_blocksizes(BlockConf *conf, Error **errp)
{
BlockBackend *blk = conf->blk;
BlockSizes blocksizes;
conf->logical_block_size = BDRV_SECTOR_SIZE;
}
}
+
+ if (conf->logical_block_size > conf->physical_block_size) {
+ error_setg(errp,
+ "logical_block_size > physical_block_size not supported");
+ return false;
+ }
+
+ if (!QEMU_IS_ALIGNED(conf->min_io_size, conf->logical_block_size)) {
+ error_setg(errp,
+ "min_io_size must be a multiple of logical_block_size");
+ return false;
+ }
+
+ if (!QEMU_IS_ALIGNED(conf->opt_io_size, conf->logical_block_size)) {
+ error_setg(errp,
+ "opt_io_size must be a multiple of logical_block_size");
+ return false;
+ }
+
+ if (conf->discard_granularity != -1 &&
+ !QEMU_IS_ALIGNED(conf->discard_granularity,
+ conf->logical_block_size)) {
+ error_setg(errp, "discard_granularity must be "
+ "a multiple of logical_block_size");
+ return false;
+ }
+
+ return true;
}
bool blkconf_apply_backend_options(BlockConf *conf, bool readonly,
read_only = !blk_bs(dev->conf.blk) || blk_is_read_only(dev->conf.blk);
}
- blkconf_blocksizes(&dev->conf);
+ if (!blkconf_blocksizes(&dev->conf, errp)) {
+ return;
+ }
+
if (dev->conf.logical_block_size != 512 ||
dev->conf.physical_block_size != 512)
{
static void nvme_init_blk(NvmeCtrl *n, Error **errp)
{
- blkconf_blocksizes(&n->conf);
+ if (!blkconf_blocksizes(&n->conf, errp)) {
+ return;
+ }
blkconf_apply_backend_options(&n->conf, blk_is_read_only(n->conf.blk),
false, errp);
}
assert(ret == 0);
}
- blkconf_blocksizes(&dev->conf);
+ if (!blkconf_blocksizes(&dev->conf, errp)) {
+ return;
+ }
+
if (dev->conf.logical_block_size != 512 ||
dev->conf.physical_block_size != 512)
{
return;
}
- blkconf_blocksizes(&conf->conf);
-
- if (conf->conf.logical_block_size >
- conf->conf.physical_block_size) {
- error_setg(errp,
- "logical_block_size > physical_block_size not supported");
+ if (!blkconf_blocksizes(&conf->conf, errp)) {
return;
}
return;
}
- blkconf_blocksizes(conf);
-
- if (conf->logical_block_size > conf->physical_block_size) {
- error_setg(
- errp, "logical_block_size > physical_block_size not supported");
+ if (!blkconf_blocksizes(conf, errp)) {
return;
}
return;
}
- blkconf_blocksizes(&dev->conf);
+ if (!blkconf_blocksizes(&dev->conf, errp)) {
+ return;
+ }
+
if (dev->conf.logical_block_size != 512) {
error_setg(errp, "logical_block_size must be 512 for IDE");
return;
return;
}
- blkconf_blocksizes(&s->qdev.conf);
-
- if (s->qdev.conf.logical_block_size >
- s->qdev.conf.physical_block_size) {
- error_setg(errp,
- "logical_block_size > physical_block_size not supported");
+ if (!blkconf_blocksizes(&s->qdev.conf, errp)) {
return;
}
if (s->qdev.conf.blk) {
ctx = blk_get_aio_context(s->qdev.conf.blk);
aio_context_acquire(ctx);
- blkconf_blocksizes(&s->qdev.conf);
+ if (!blkconf_blocksizes(&s->qdev.conf, errp)) {
+ goto out;
+ }
}
s->qdev.blocksize = s->qdev.conf.logical_block_size;
s->qdev.type = TYPE_DISK;
s->product = g_strdup("QEMU HARDDISK");
}
scsi_realize(&s->qdev, errp);
+out:
if (ctx) {
aio_context_release(ctx);
}
return;
}
- blkconf_blocksizes(&s->conf);
+ if (!blkconf_blocksizes(&s->conf, errp)) {
+ return;
+ }
+
if (!blkconf_apply_backend_options(&s->conf, blk_is_read_only(blk), true,
errp)) {
return;
bool blkconf_geometry(BlockConf *conf, int *trans,
unsigned cyls_max, unsigned heads_max, unsigned secs_max,
Error **errp);
-void blkconf_blocksizes(BlockConf *conf);
+bool blkconf_blocksizes(BlockConf *conf, Error **errp);
bool blkconf_apply_backend_options(BlockConf *conf, bool readonly,
bool resizable, Error **errp);
drive-type = "144"
Testing: -drive if=none,file=TEST_DIR/t.qcow2 -device floppy,drive=none0,logical_block_size=4096
-QEMU_PROG: -device floppy,drive=none0,logical_block_size=4096: Physical and logical block size must be 512 for floppy
+QEMU_PROG: -device floppy,drive=none0,logical_block_size=4096: logical_block_size > physical_block_size not supported
Testing: -drive if=none,file=TEST_DIR/t.qcow2 -device floppy,drive=none0,physical_block_size=1024
QEMU_PROG: -device floppy,drive=none0,physical_block_size=1024: Physical and logical block size must be 512 for floppy