The Maxim fuel gauge datasheets describe the interrupt line as active
low with a requirement of acknowledge from the CPU. The falling edge
interrupt will mostly work but it's not correct.
Fixes: f48b5050c301 ("ARM: dts: exynos: add Samsung's Exynos4412-based P4 Note boards")
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Link: https://lore.kernel.org/r/20201210212534.216197-2-krzk@kernel.org
pinctrl-0 = <&fuel_alert_irq>;
pinctrl-names = "default";
interrupt-parent = <&gpx2>;
- interrupts = <3 IRQ_TYPE_EDGE_FALLING>;
+ interrupts = <3 IRQ_TYPE_LEVEL_LOW>;
maxim,rsns-microohm = <10000>;
maxim,over-heat-temp = <600>;
maxim,over-volt = <4300>;