If correctly configured allow the STM32F2xx timer to print
out the PWM duty cycle information.
Signed-off-by: Alistair Francis <alistair@alistair23.me>
Reviewed-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Message-id:
cdb59039a25e061615713a94b40797baa12ea9f9.
1474742262.git.alistair@alistair23.me
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
qemu_irq_pulse(s->irq);
stm32f2xx_timer_set_alarm(s, s->hit_time);
}
+
+ if (s->tim_ccmr1 & (TIM_CCMR1_OC2M2 | TIM_CCMR1_OC2M1) &&
+ !(s->tim_ccmr1 & TIM_CCMR1_OC2M0) &&
+ s->tim_ccmr1 & TIM_CCMR1_OC2PE &&
+ s->tim_ccer & TIM_CCER_CC2E) {
+ /* PWM 2 - Mode 1 */
+ DB_PRINT("PWM2 Duty Cycle: %d%%\n",
+ s->tim_ccr2 / (100 * (s->tim_psc + 1)));
+ }
}
static inline int64_t stm32f2xx_ns_to_ticks(STM32F2XXTimerState *s, int64_t t)