Since the clock scaling is based on fb divider adjustments,
make sure the other pll parameters are the same.
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Reviewed-by: Christian König <christian.koenig@amd.com>
        if (ret)
                return ret;
 
+       if ((min_dividers.ref_div != max_dividers.ref_div) ||
+           (min_dividers.post_div != max_dividers.post_div) ||
+           (max_dividers.ref_div != current_max_dividers.ref_div) ||
+           (max_dividers.post_div != current_max_dividers.post_div))
+               return -EINVAL;
+
        rs780_force_fbdiv(rdev, max_dividers.fb_div);
 
        if (max_dividers.fb_div > min_dividers.fb_div) {