[ Upstream commit
55840b9eae5367b5d5b29619dc2fb7e4596dba46 ]
Commit
b50aa49638c7 ("hwmon: (lm90) Prevent integer underflows of
temperature calculations") addressed a number of underflow situations
when writing temperature limits. However, it missed one situation, seen
when an attempt is made to set the hysteresis value to MAX_LONG and the
critical temperature limit is negative.
Use clamp_val() when setting the hysteresis temperature to ensure that
the provided value can never overflow or underflow.
Fixes: b50aa49638c7 ("hwmon: (lm90) Prevent integer underflows of temperature calculations")
Cc: Dmitry Osipenko <digetx@gmail.com>
Reviewed-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Sasha Levin <sashal@kernel.org>
else
temp = temp_from_s8(data->temp8[LOCAL_CRIT]);
- /* prevent integer underflow */
- val = max(val, -128000l);
+ /* prevent integer overflow/underflow */
+ val = clamp_val(val, -128000l, 255000l);
data->temp_hyst = hyst_to_reg(temp - val);
err = i2c_smbus_write_byte_data(client, LM90_REG_W_TCRIT_HYST,