Holger Hoffstätte observed that Samsung 850 Pro may return invalid
temperatures for a short period of time after resume. Return -ENODATA
to userspace if this is observed.
Fixes: 5b46903d8bf3 ("hwmon: Driver for disk and solid state drives with temperature sensors")
Reported-by: Holger Hoffstätte <holger@applied-asynchrony.com>
Cc: Holger Hoffstätte <holger@applied-asynchrony.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
return err;
switch (attr) {
case hwmon_temp_input:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP]);
break;
case hwmon_temp_lowest:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP_LOWEST]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP_LOWEST]);
break;
case hwmon_temp_highest:
+ if (!temp_is_valid(buf[SCT_STATUS_TEMP_HIGHEST]))
+ return -ENODATA;
*val = temp_from_sct(buf[SCT_STATUS_TEMP_HIGHEST]);
break;
default: