dt-bindings: net: dp83826: support TX data voltage tuning
authorCatalin Popescu <catalin.popescu@leica-geosystems.com>
Tue, 13 Feb 2024 08:07:04 +0000 (09:07 +0100)
committerDavid S. Miller <davem@davemloft.net>
Wed, 14 Feb 2024 12:06:09 +0000 (12:06 +0000)
Add properties ti,cfg-dac-minus-one-bp/ti,cfg-dac-plus-one-bp
to support voltage tuning of logical levels -1/+1 of the MLT-3
encoded TX data.

Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Catalin Popescu <catalin.popescu@leica-geosystems.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Documentation/devicetree/bindings/net/ti,dp83822.yaml

index db74474207ed473a60c49efa4914eeed33452a84..8f4350be689c57d351ce882a74ab5f6c7745e6f6 100644 (file)
@@ -62,6 +62,24 @@ properties:
        for the PHY.  The internal delay for the PHY is fixed to 3.5ns relative
        to transmit data.
 
+  ti,cfg-dac-minus-one-bp:
+    description: |
+       DP83826 PHY only.
+       Sets the voltage ratio (with respect to the nominal value)
+       of the logical level -1 for the MLT-3 encoded TX data.
+    enum: [5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, 10000,
+           10625, 11250, 11875, 12500, 13125, 13750, 14375, 15000]
+    default: 10000
+
+  ti,cfg-dac-plus-one-bp:
+    description: |
+       DP83826 PHY only.
+       Sets the voltage ratio (with respect to the nominal value)
+       of the logical level +1 for the MLT-3 encoded TX data.
+    enum: [5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, 10000,
+           10625, 11250, 11875, 12500, 13125, 13750, 14375, 15000]
+    default: 10000
+
 required:
   - reg