bug fix in the handling of the internal device reset event
The reason code check in scsih_sas_device_status_change_event never
evaluates as true for internal device reset, hence driver never quiesce s IO
when firmware is sending a device reset. The fix is to change the
evaluate to:
if (event_data->ReasonCode !=
    MPI2_EVENT_SAS_DEV_STAT_RC_INTERNAL_DEVICE_RESET &&
   event_data->ReasonCode !=
    MPI2_EVENT_SAS_DEV_STAT_RC_CMP_INTERNAL_DEV_RESET)
        return;
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
                     event_data);
 #endif
 
-       if (!(event_data->ReasonCode ==
+       if (event_data->ReasonCode !=
            MPI2_EVENT_SAS_DEV_STAT_RC_INTERNAL_DEVICE_RESET &&
-          event_data->ReasonCode ==
-           MPI2_EVENT_SAS_DEV_STAT_RC_CMP_INTERNAL_DEV_RESET))
+          event_data->ReasonCode !=
+           MPI2_EVENT_SAS_DEV_STAT_RC_CMP_INTERNAL_DEV_RESET)
                return;
 
        spin_lock_irqsave(&ioc->sas_device_lock, flags);