The Energy Model (EM) can be used on platforms which are missing real
power information. Those platforms would implement .get_cost() which
populates needed values for the Energy Aware Scheduler (EAS). The EAS
doesn't use 'power' fields from EM, but other frameworks might use them.
Thus, to avoid miss-usage of this specific type of EM, introduce a new
flags which can be checked by other frameworks.
Signed-off-by: Pierre Gondois <Pierre.Gondois@arm.com>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
  *
  *  EM_PERF_DOMAIN_SKIP_INEFFICIENCIES: Skip inefficient states when estimating
  *  energy consumption.
+ *
+ *  EM_PERF_DOMAIN_ARTIFICIAL: The power values are artificial and might be
+ *  created by platform missing real power information
  */
 #define EM_PERF_DOMAIN_MILLIWATTS BIT(0)
 #define EM_PERF_DOMAIN_SKIP_INEFFICIENCIES BIT(1)
+#define EM_PERF_DOMAIN_ARTIFICIAL BIT(2)
 
 #define em_span_cpus(em) (to_cpumask((em)->cpus))
+#define em_is_artificial(em) ((em)->flags & EM_PERF_DOMAIN_ARTIFICIAL)
 
 #ifdef CONFIG_ENERGY_MODEL
 #define EM_MAX_POWER 0xFFFF
 
 
        if (milliwatts)
                dev->em_pd->flags |= EM_PERF_DOMAIN_MILLIWATTS;
+       else if (cb->get_cost)
+               dev->em_pd->flags |= EM_PERF_DOMAIN_ARTIFICIAL;
 
        em_cpufreq_update_efficiencies(dev);