From: Alistair Francis Date: Fri, 19 Jun 2015 04:16:48 +0000 (-0700) Subject: s3adsp1800: Remove the hardcoded values from the reset X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=033af8e9aaba1994c4816cea5828aaddc383a907;p=qemu.git s3adsp1800: Remove the hardcoded values from the reset Remove the hardcoded values from the machine specific reset function, as the same values are already set in the standard MicroBlaze reset. This also allows the entire reset function to be deleted, as PVR registers are now preserved on reset. Signed-off-by: Alistair Francis Reviewed-by: Edgar E. Iglesias Reviewed-by: Peter Crosthwaite Signed-off-by: Edgar E. Iglesias --- diff --git a/hw/microblaze/petalogix_s3adsp1800_mmu.c b/hw/microblaze/petalogix_s3adsp1800_mmu.c index 4dbbd1e5d2..0c2140c3f8 100644 --- a/hw/microblaze/petalogix_s3adsp1800_mmu.c +++ b/hw/microblaze/petalogix_s3adsp1800_mmu.c @@ -51,13 +51,6 @@ #define ETHLITE_IRQ 1 #define UARTLITE_IRQ 3 -static void machine_cpu_reset(MicroBlazeCPU *cpu) -{ - CPUMBState *env = &cpu->env; - - env->pvr.regs[10] = 0x0c000000; /* spartan 3a dsp family. */ -} - static void petalogix_s3adsp1800_init(MachineState *machine) { @@ -128,7 +121,7 @@ petalogix_s3adsp1800_init(MachineState *machine) microblaze_load_kernel(cpu, ddr_base, ram_size, machine->initrd_filename, BINARY_DEVICE_TREE_FILE, - machine_cpu_reset); + NULL); } static QEMUMachine petalogix_s3adsp1800_machine = {