From: Matthias Kaehlcke Date: Tue, 31 Jul 2018 18:59:14 +0000 (-0700) Subject: dt-bindings: thermal: qcom-spmi-temp-alarm: Improve thermal zone in example X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=97b27dd33d592b14cfb9299d5c89167ec57a3b83;p=linux.git dt-bindings: thermal: qcom-spmi-temp-alarm: Improve thermal zone in example The current example for a thermal zone isn't very useful as reference since it would result in a hardware shutdown at 145°C, instead of allowing the system to try to shutdown gracefully. Without an ADC channel a maximum of two trip points is useful in practice for this sensor, with temperatures corresponding to the stage 1 and stage 2 'hardware trip points'. A critical trip point at stage 2 may allow the system to shutdown before a hardware shutdown at stage 3 kicks in. It should be noted though that by default the chip performs a 'partial shutdown' when the temperature reaches stage 2, which may prevent an orderly shutdown. The 'partial shutdown' can be disabled by software. Signed-off-by: Matthias Kaehlcke Reviewed-by: Douglas Anderson Reviewed-by: Rob Herring Signed-off-by: Eduardo Valentin --- diff --git a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt index 86fb41fe772f9..0273a92a2a849 100644 --- a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt +++ b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt @@ -35,19 +35,14 @@ Example: thermal-sensors = <&pm8941_temp>; trips { - passive { - temperature = <1050000>; + stage1 { + temperature = <105000>; hysteresis = <2000>; type = "passive"; }; - alert { + stage2 { temperature = <125000>; hysteresis = <2000>; - type = "hot"; - }; - crit { - temperature = <145000>; - hysteresis = <2000>; type = "critical"; }; };