From: Johan Hovold Date: Thu, 18 Mar 2021 15:57:49 +0000 (+0100) Subject: net: cdc-phonet: fix data-interface release on probe failure X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=c79a707072fe3fea0e3c92edee6ca85c1e53c29f;p=linux.git net: cdc-phonet: fix data-interface release on probe failure Set the disconnected flag before releasing the data interface in case netdev registration fails to avoid having the disconnect callback try to deregister the never registered netdev (and trigger a WARN_ON()). Fixes: 87cf65601e17 ("USB host CDC Phonet network interface driver") Signed-off-by: Johan Hovold Signed-off-by: David S. Miller --- diff --git a/drivers/net/usb/cdc-phonet.c b/drivers/net/usb/cdc-phonet.c index 02e6bbb17b15d..8d1f69dad6031 100644 --- a/drivers/net/usb/cdc-phonet.c +++ b/drivers/net/usb/cdc-phonet.c @@ -387,6 +387,8 @@ static int usbpn_probe(struct usb_interface *intf, const struct usb_device_id *i err = register_netdev(dev); if (err) { + /* Set disconnected flag so that disconnect() returns early. */ + pnd->disconnected = 1; usb_driver_release_interface(&usbpn_driver, data_intf); goto out; }