From: Javier Carrasco Date: Fri, 17 Nov 2023 06:40:35 +0000 (+0100) Subject: ABI: sysfs-class-hwmon: document missing humidity attributes X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=d0d710554ef0454a97dde2c114f7d5b2a3c2b4de;p=linux.git ABI: sysfs-class-hwmon: document missing humidity attributes All these attributes already exist and are used by the hwmon subsystem, but they still must be documented. The missing attributes are the following: - humidityY_alarm - humidityY_fault - humidityY_label - humidityY_max - humidityY_max_hyst - humidityY_min - humidityY_min_hyst Add the missing humidity attributes to the ABI documentation according to their current usage and access rights in the hwmon subsystem. Signed-off-by: Javier Carrasco Link: https://lore.kernel.org/r/20231116-hwmon_abi-v1-2-8bfb7f51145a@gmail.com Signed-off-by: Guenter Roeck --- diff --git a/Documentation/ABI/testing/sysfs-class-hwmon b/Documentation/ABI/testing/sysfs-class-hwmon index b998a42add95d..dccbcdc2dad87 100644 --- a/Documentation/ABI/testing/sysfs-class-hwmon +++ b/Documentation/ABI/testing/sysfs-class-hwmon @@ -887,6 +887,15 @@ Description: RW +What: /sys/class/hwmon/hwmonX/humidityY_alarm +Description: + Humidity limit detection + + - 0: OK + - 1: Humidity limit has been reached + + RO + What: /sys/class/hwmon/hwmonX/humidityY_enable Description: Enable or disable the sensors @@ -899,6 +908,15 @@ Description: RW +What: /sys/class/hwmon/hwmonX/humidityY_fault +Description: + Reports a humidity sensor failure. + + - 1: Failed + - 0: Ok + + RO + What: /sys/class/hwmon/hwmonX/humidityY_input Description: Humidity @@ -907,6 +925,57 @@ Description: RO +What: /sys/class/hwmon/hwmonX/humidityY_label +Description: + Suggested humidity channel label. + + Text string + + Should only be created if the driver has hints about what + this humidity channel is being used for, and user-space + doesn't. In all other cases, the label is provided by + user-space. + + RO + +What: /sys/class/hwmon/hwmonX/humidityY_max +Description: + Humidity max value. + + Unit: milli-percent (per cent mille, pcm) + + RW + +What: /sys/class/hwmon/hwmonX/humidityY_max_hyst +Description: + Humidity hysteresis value for max limit. + + Unit: milli-percent (per cent mille, pcm) + + Must be reported as an absolute humidity, NOT a delta + from the max value. + + RW + +What: /sys/class/hwmon/hwmonX/humidityY_min +Description: + Humidity min value. + + Unit: milli-percent (per cent mille, pcm) + + RW + +What: /sys/class/hwmon/hwmonX/humidityY_min_hyst +Description: + Humidity hysteresis value for min limit. + + Unit: milli-percent (per cent mille, pcm) + + Must be reported as an absolute humidity, NOT a delta + from the min value. + + RW + What: /sys/class/hwmon/hwmonX/humidityY_rated_min Description: Minimum rated humidity.