From: Kalle Komierowski Date: Thu, 2 Feb 2012 15:05:46 +0000 (+0100) Subject: ab8500_fg: Don't clear the CCMuxOffset bit X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=e32ad07cea1f198db1cc6c2055dd8471b562a535;p=linux.git ab8500_fg: Don't clear the CCMuxOffset bit The CCMuxOffset bit is not kept set. This will force the columb counter of the AB8500 to use the measure offset calibration. This should increase the accuracy of the fuel gauge. Signed-off-by: Kalle Komierowski Signed-off-by: Marcus Cooper Signed-off-by: Lee Jones Reviewed-by: Jonas ABERG --- diff --git a/drivers/power/ab8500_fg.c b/drivers/power/ab8500_fg.c index ed62ef788eb53..5a9f58d4c0fb1 100644 --- a/drivers/power/ab8500_fg.c +++ b/drivers/power/ab8500_fg.c @@ -484,8 +484,9 @@ static int ab8500_fg_coulomb_counter(struct ab8500_fg *di, bool enable) di->flags.fg_enabled = true; } else { /* Clear any pending read requests */ - ret = abx500_set_register_interruptible(di->dev, - AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG, 0); + ret = abx500_mask_and_set_register_interruptible(di->dev, + AB8500_GAS_GAUGE, AB8500_GASG_CC_CTRL_REG, + (RESET_ACCU | READ_REQ), 0); if (ret) goto cc_err; @@ -1403,8 +1404,7 @@ static void ab8500_fg_algorithm_discharging(struct ab8500_fg *di) sleep_time = di->bat->fg_params->init_timer; /* Discard the first [x] seconds */ - if (di->init_cnt > - di->bat->fg_params->init_discard_time) { + if (di->init_cnt > di->bat->fg_params->init_discard_time) { ab8500_fg_calc_cap_discharge_voltage(di, true); ab8500_fg_check_capacity_limits(di, true);