From: Fabio Estevam Date: Sat, 28 Mar 2020 18:53:26 +0000 (-0300) Subject: dt-bindings: clock: syscon-icst: Remove unneeded unit name X-Git-Url: http://git.maquefel.me/?a=commitdiff_plain;h=ec76f57d62669a396e6f519cdf99e3522246e3f5;p=linux.git dt-bindings: clock: syscon-icst: Remove unneeded unit name The following warnings are seen with 'make dt_binding_check': Documentation/devicetree/bindings/clock/arm,syscon-icst.example.dts:17.16-24.11: Warning (unit_address_vs_reg): /example-0/clock@00: node has a unit name, but no reg or ranges property Documentation/devicetree/bindings/clock/arm,syscon-icst.example.dts:17.16-24.11: Warning (unit_address_format): /example-0/clock@00: unit name should not have leading 0s Fix them by removing the unneeded clock unit name. Signed-off-by: Fabio Estevam Signed-off-by: Rob Herring --- diff --git a/Documentation/devicetree/bindings/clock/arm,syscon-icst.yaml b/Documentation/devicetree/bindings/clock/arm,syscon-icst.yaml index de9a465096dbd..444aeea27db83 100644 --- a/Documentation/devicetree/bindings/clock/arm,syscon-icst.yaml +++ b/Documentation/devicetree/bindings/clock/arm,syscon-icst.yaml @@ -91,7 +91,7 @@ required: examples: - | - vco1: clock@00 { + vco1: clock { compatible = "arm,impd1-vco1"; #clock-cells = <0>; lock-offset = <0x08>;