From 14533a5a6c12e8d7de79d309d4085bf186058fe1 Mon Sep 17 00:00:00 2001 From: Michael Kao Date: Mon, 23 Mar 2020 20:15:35 +0800 Subject: [PATCH] thermal/drivers/mediatek: Fix bank number settings on mt8183 MT8183_NUM_ZONES should be set to 1 because MT8183 doesn't have multiple banks. Fixes: a4ffe6b52d27 ("thermal: mediatek: add support for MT8183") Signed-off-by: Michael Kao Signed-off-by: Hsin-Yi Wang Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20200323121537.22697-6-michael.kao@mediatek.com --- drivers/thermal/mtk_thermal.c | 5 ++++- 1 file changed, 4 insertions(+), 1 deletion(-) diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c index 76e30603d4d58..6b7ef1993d7e2 100644 --- a/drivers/thermal/mtk_thermal.c +++ b/drivers/thermal/mtk_thermal.c @@ -211,6 +211,9 @@ enum { /* The total number of temperature sensors in the MT8183 */ #define MT8183_NUM_SENSORS 6 +/* The number of banks in the MT8183 */ +#define MT8183_NUM_ZONES 1 + /* The number of sensing points per bank */ #define MT8183_NUM_SENSORS_PER_ZONE 6 @@ -497,7 +500,7 @@ static const struct mtk_thermal_data mt7622_thermal_data = { */ static const struct mtk_thermal_data mt8183_thermal_data = { .auxadc_channel = MT8183_TEMP_AUXADC_CHANNEL, - .num_banks = MT8183_NUM_SENSORS_PER_ZONE, + .num_banks = MT8183_NUM_ZONES, .num_sensors = MT8183_NUM_SENSORS, .vts_index = mt8183_vts_index, .cali_val = MT8183_CALIBRATION, -- 2.30.2