From 96fc3a45ea073136566f3c2676cad52f8b39a7df Mon Sep 17 00:00:00 2001 From: Joakim Tjernlund <Joakim.Tjernlund@transmode.se> Date: Tue, 29 Jun 2010 15:05:34 -0700 Subject: [PATCH] rtc: fix ds1388 time corruption The ds1307 driver misreads the ds1388 registers when checking for 12 or 24 hour mode. Instead of checking the hour register it reads the minute register. Therefore the driver thinks minutes >= 40 has the 12HR bit set and resets the minute register by zeroing the high bits. This results in minutes are reset to 0-9, jumping back in time 40 or 50 minutes. The time jump is also written back to the RTC. Signed-off-by: Joakim Tjernlund <Joakim.Tjernlund@transmode.se> Cc: Wan ZongShun <mcuos.com@gmail.com> Cc: Alessandro Zummo <a.zummo@towertech.it> Cc: Paul Gortmaker <p_gortmaker@yahoo.com> Cc: <stable@kernel.org> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org> --- drivers/rtc/rtc-ds1307.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/rtc/rtc-ds1307.c b/drivers/rtc/rtc-ds1307.c index de033b7ac21f6..d827ce570a8c8 100644 --- a/drivers/rtc/rtc-ds1307.c +++ b/drivers/rtc/rtc-ds1307.c @@ -777,7 +777,7 @@ static int __devinit ds1307_probe(struct i2c_client *client, read_rtc: /* read RTC registers */ - tmp = ds1307->read_block_data(ds1307->client, 0, 8, buf); + tmp = ds1307->read_block_data(ds1307->client, ds1307->offset, 8, buf); if (tmp != 8) { pr_debug("read error %d\n", tmp); err = -EIO; @@ -862,7 +862,7 @@ read_rtc: if (ds1307->regs[DS1307_REG_HOUR] & DS1307_BIT_PM) tmp += 12; i2c_smbus_write_byte_data(client, - DS1307_REG_HOUR, + ds1307->offset + DS1307_REG_HOUR, bin2bcd(tmp)); } -- 2.30.2