From bb8f32c0318cb6c6e13e09ec0f35e21eff246413 Mon Sep 17 00:00:00 2001
From: =?utf8?q?Herv=C3=A9=20Poussineau?= <hpoussin@reactos.org>
Date: Thu, 25 Feb 2016 13:45:32 +0100
Subject: [PATCH] i8257: fix Terminal Count status
MIME-Version: 1.0
Content-Type: text/plain; charset=utf8
Content-Transfer-Encoding: 8bit

When a DMA transfer is done (ie all bytes have been transfered), the corresponding
Terminal Count bit must be set in the status register.
This bit is already cleared in i8257_read_cont and i8257_write_cont when required.

This fixes (at least) floppy transfer in IBM 40p firmware, which checks in DMA
controller if everything went fine.

Signed-off-by: Hervé Poussineau <hpoussin@reactos.org>
Message-Id: <1456404332-31556-1-git-send-email-hpoussin@reactos.org>
Reviewed-by: John Snow <jsnow@redhat.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
---
 hw/dma/i8257.c | 4 ++++
 1 file changed, 4 insertions(+)

diff --git a/hw/dma/i8257.c b/hw/dma/i8257.c
index 5a52707ae2..6078893efb 100644
--- a/hw/dma/i8257.c
+++ b/hw/dma/i8257.c
@@ -342,6 +342,10 @@ static void i8257_channel_run(I8257State *d, int ichan)
                              r->now[COUNT], (r->base[COUNT] + 1) << ncont);
     r->now[COUNT] = n;
     ldebug ("dma_pos %d size %d\n", n, (r->base[COUNT] + 1) << ncont);
+    if (n == (r->base[COUNT] + 1) << ncont) {
+        ldebug("transfer done\n");
+        d->status |= (1 << ichan);
+    }
 }
 
 static void i8257_dma_run(void *opaque)
-- 