From ccc66c6092802d682537227136dcbd0527027e6f Mon Sep 17 00:00:00 2001 From: Ian Rogers Date: Tue, 2 May 2023 15:38:10 -0700 Subject: [PATCH] perf metric: JSON flag to not group events if gathering a metric group Some metric groups have metrics that don't have fully overlapping events, meaning that the group's events become unique event groups that may need to multiplex with each other. This can be particularly unfortunate when the groups wouldn't need to multiplex because there are sufficient hardware counters. Add a flag so that if recording a metric group then the metrics within the group needn't use groups for their events. The flag is added to Intel TopdownL1 and TopdownL2 metrics. Signed-off-by: Ian Rogers Tested-by: Kan Liang Cc: Adrian Hunter Cc: Ahmad Yasin Cc: Alexander Shishkin Cc: Andi Kleen Cc: Athira Rajeev Cc: Caleb Biggers Cc: Edward Baker Cc: Florian Fischer Cc: Ingo Molnar Cc: James Clark Cc: Jiri Olsa Cc: John Garry Cc: Kajol Jain Cc: Kang Minchul Cc: Leo Yan Cc: Mark Rutland Cc: Namhyung Kim Cc: Perry Taylor Cc: Peter Zijlstra Cc: Ravi Bangoria Cc: Rob Herring Cc: Samantha Alt Cc: Stephane Eranian Cc: Sumanth Korikkar Cc: Suzuki Poulouse Cc: Thomas Richter Cc: Tiezhu Yang Cc: Weilin Wang Cc: Xing Zhengjun Cc: Yang Jihong Link: https://lore.kernel.org/r/20230502223851.2234828-4-irogers@google.com Signed-off-by: Arnaldo Carvalho de Melo --- .../arch/x86/alderlake/adl-metrics.json | 26 +++++++++++++++++++ .../arch/x86/alderlaken/adln-metrics.json | 14 ++++++++++ .../arch/x86/broadwell/bdw-metrics.json | 12 +++++++++ .../arch/x86/broadwellde/bdwde-metrics.json | 12 +++++++++ .../arch/x86/broadwellx/bdx-metrics.json | 12 +++++++++ .../arch/x86/cascadelakex/clx-metrics.json | 12 +++++++++ .../arch/x86/haswell/hsw-metrics.json | 12 +++++++++ .../arch/x86/haswellx/hsx-metrics.json | 12 +++++++++ .../arch/x86/icelake/icl-metrics.json | 12 +++++++++ .../arch/x86/icelakex/icx-metrics.json | 12 +++++++++ .../arch/x86/ivybridge/ivb-metrics.json | 12 +++++++++ .../arch/x86/ivytown/ivt-metrics.json | 12 +++++++++ .../arch/x86/jaketown/jkt-metrics.json | 12 +++++++++ .../arch/x86/sandybridge/snb-metrics.json | 12 +++++++++ .../arch/x86/sapphirerapids/spr-metrics.json | 12 +++++++++ .../arch/x86/skylake/skl-metrics.json | 12 +++++++++ .../arch/x86/skylakex/skx-metrics.json | 12 +++++++++ .../arch/x86/tigerlake/tgl-metrics.json | 12 +++++++++ tools/perf/pmu-events/jevents.py | 4 ++- tools/perf/pmu-events/pmu-events.h | 1 + tools/perf/util/metricgroup.c | 8 +++--- 21 files changed, 240 insertions(+), 5 deletions(-) diff --git a/tools/perf/pmu-events/arch/x86/alderlake/adl-metrics.json b/tools/perf/pmu-events/arch/x86/alderlake/adl-metrics.json index 75d80e70e5cd1..1f90475539423 100644 --- a/tools/perf/pmu-events/arch/x86/alderlake/adl-metrics.json +++ b/tools/perf/pmu-events/arch/x86/alderlake/adl-metrics.json @@ -133,6 +133,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that uops must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count. The rest of these subevents count backend stalls, in cycles, due to an outstanding request which is memory bound vs core bound. The subevents are not slot based events and therefore can not be precisely added or subtracted from the Backend_Bound_Aux subevents which are slot based.", "ScaleUnit": "100%", "Unit": "cpu_atom" @@ -143,6 +144,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound_aux", "MetricThreshold": "tma_backend_bound_aux > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that UOPS must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count. All of these subevents count backend stalls, in slots, due to a resource limitation. These are not cycle based events and therefore can not be precisely added or subtracted from the Backend_Bound subevents which are cycle based. These subevents are supplementary to Backend_Bound and can be used to analyze results from a resource perspective at allocation.", "ScaleUnit": "100%", "Unit": "cpu_atom" @@ -153,6 +155,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend because allocation is stalled due to a mispredicted jump or a machine clear. Only issue slots wasted due to fast nukes such as memory ordering nukes are counted. Other nukes are not accounted for. Counts all issue slots blocked during this recovery window including relevant microcode flows and while uops are not yet available in the instruction queue (IQ). Also includes the issue slots that were consumed by the backend but were thrown away because they were younger than the mispredict or machine clear.", "ScaleUnit": "100%", "Unit": "cpu_atom" @@ -163,6 +166,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_base", "MetricThreshold": "tma_base > 0.6", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -182,6 +186,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_bad_speculation_group", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.05", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -209,6 +214,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -255,6 +261,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -264,6 +271,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.15", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -291,6 +299,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -593,6 +602,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_bad_speculation_group", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.05", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -611,6 +621,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -629,6 +640,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_ms_uops", "MetricThreshold": "tma_ms_uops > 0.05", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "Counts the number of uops that are from the complex flows issued by the micro-sequencer (MS). This includes uops from flows due to complex instructions, faults, assists, and inserted flows.", "ScaleUnit": "100%", "Unit": "cpu_atom" @@ -729,6 +741,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_aux_group", "MetricName": "tma_resource_bound", "MetricThreshold": "tma_resource_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that uops must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count.", "ScaleUnit": "100%", "Unit": "cpu_atom" @@ -739,6 +752,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.75", + "MetricgroupNoGroup": "TopdownL1", "ScaleUnit": "100%", "Unit": "cpu_atom" }, @@ -848,6 +862,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -858,6 +873,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -868,6 +884,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: TOPDOWN.BR_MISPREDICT_SLOTS. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -919,6 +936,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -1031,6 +1049,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 6 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -1041,6 +1060,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -1121,6 +1141,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -1141,6 +1162,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences. Sample with: UOPS_RETIRED.HEAVY", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -2023,6 +2045,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -2082,6 +2105,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -2112,6 +2136,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%", "Unit": "cpu_core" @@ -2310,6 +2335,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%", "Unit": "cpu_core" diff --git a/tools/perf/pmu-events/arch/x86/alderlaken/adln-metrics.json b/tools/perf/pmu-events/arch/x86/alderlaken/adln-metrics.json index 1a85d935c733c..0402adbf7d927 100644 --- a/tools/perf/pmu-events/arch/x86/alderlaken/adln-metrics.json +++ b/tools/perf/pmu-events/arch/x86/alderlaken/adln-metrics.json @@ -98,6 +98,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that uops must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count. The rest of these subevents count backend stalls, in cycles, due to an outstanding request which is memory bound vs core bound. The subevents are not slot based events and therefore can not be precisely added or subtracted from the Backend_Bound_Aux subevents which are slot based.", "ScaleUnit": "100%" }, @@ -107,6 +108,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound_aux", "MetricThreshold": "tma_backend_bound_aux > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that UOPS must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count. All of these subevents count backend stalls, in slots, due to a resource limitation. These are not cycle based events and therefore can not be precisely added or subtracted from the Backend_Bound subevents which are cycle based. These subevents are supplementary to Backend_Bound and can be used to analyze results from a resource perspective at allocation.", "ScaleUnit": "100%" }, @@ -116,6 +118,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend because allocation is stalled due to a mispredicted jump or a machine clear. Only issue slots wasted due to fast nukes such as memory ordering nukes are counted. Other nukes are not accounted for. Counts all issue slots blocked during this recovery window including relevant microcode flows and while uops are not yet available in the instruction queue (IQ). Also includes the issue slots that were consumed by the backend but were thrown away because they were younger than the mispredict or machine clear.", "ScaleUnit": "100%" }, @@ -125,6 +128,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_base", "MetricThreshold": "tma_base > 0.6", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -142,6 +146,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_bad_speculation_group", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.05", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -166,6 +171,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -207,6 +213,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -215,6 +222,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.15", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -239,6 +247,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "ScaleUnit": "100%" }, { @@ -499,6 +508,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_bad_speculation_group", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.05", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -515,6 +525,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "ScaleUnit": "100%" }, { @@ -531,6 +542,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_ms_uops", "MetricThreshold": "tma_ms_uops > 0.05", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "Counts the number of uops that are from the complex flows issued by the micro-sequencer (MS). This includes uops from flows due to complex instructions, faults, assists, and inserted flows.", "ScaleUnit": "100%" }, @@ -620,6 +632,7 @@ "MetricGroup": "TopdownL2;tma_L2_group;tma_backend_bound_aux_group", "MetricName": "tma_resource_bound", "MetricThreshold": "tma_resource_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "Counts the total number of issue slots that were not consumed by the backend due to backend stalls. Note that uops must be available for consumption in order for this event to count. If a uop is not available (IQ is empty), this event will not count.", "ScaleUnit": "100%" }, @@ -629,6 +642,7 @@ "MetricGroup": "TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.75", + "MetricgroupNoGroup": "TopdownL1", "ScaleUnit": "100%" }, { diff --git a/tools/perf/pmu-events/arch/x86/broadwell/bdw-metrics.json b/tools/perf/pmu-events/arch/x86/broadwell/bdw-metrics.json index 51cf8560a8d38..f9e2316601e1e 100644 --- a/tools/perf/pmu-events/arch/x86/broadwell/bdw-metrics.json +++ b/tools/perf/pmu-events/arch/x86/broadwell/bdw-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -170,6 +173,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -263,6 +267,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -272,6 +277,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -326,6 +332,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -335,6 +342,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -828,6 +836,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -858,6 +867,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -886,6 +896,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1048,6 +1059,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/broadwellde/bdwde-metrics.json b/tools/perf/pmu-events/arch/x86/broadwellde/bdwde-metrics.json index fb57c73824084..e9c46d336a8e0 100644 --- a/tools/perf/pmu-events/arch/x86/broadwellde/bdwde-metrics.json +++ b/tools/perf/pmu-events/arch/x86/broadwellde/bdwde-metrics.json @@ -97,6 +97,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%" }, @@ -106,6 +107,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -116,6 +118,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: TOPDOWN.BR_MISPREDICT_SLOTS. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -164,6 +167,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -248,6 +252,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -257,6 +262,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -311,6 +317,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -320,6 +327,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -795,6 +803,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -825,6 +834,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -853,6 +863,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1013,6 +1024,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/broadwellx/bdx-metrics.json b/tools/perf/pmu-events/arch/x86/broadwellx/bdx-metrics.json index 65ec0c9e55d12..437b9867acb9f 100644 --- a/tools/perf/pmu-events/arch/x86/broadwellx/bdx-metrics.json +++ b/tools/perf/pmu-events/arch/x86/broadwellx/bdx-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -170,6 +173,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -263,6 +267,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -272,6 +277,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -326,6 +332,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -335,6 +342,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -829,6 +837,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -869,6 +878,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -897,6 +907,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1079,6 +1090,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/cascadelakex/clx-metrics.json b/tools/perf/pmu-events/arch/x86/cascadelakex/clx-metrics.json index 8f7dc72accd06..875c766222e36 100644 --- a/tools/perf/pmu-events/arch/x86/cascadelakex/clx-metrics.json +++ b/tools/perf/pmu-events/arch/x86/cascadelakex/clx-metrics.json @@ -101,6 +101,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -110,6 +111,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -120,6 +122,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -167,6 +170,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -271,6 +275,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -280,6 +285,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -354,6 +360,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -372,6 +379,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1142,6 +1150,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1196,6 +1205,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1224,6 +1234,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1458,6 +1469,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/haswell/hsw-metrics.json b/tools/perf/pmu-events/arch/x86/haswell/hsw-metrics.json index 2528418200bb8..9570a88d6d1c1 100644 --- a/tools/perf/pmu-events/arch/x86/haswell/hsw-metrics.json +++ b/tools/perf/pmu-events/arch/x86/haswell/hsw-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -161,6 +164,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -254,6 +258,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -263,6 +268,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -272,6 +278,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -281,6 +288,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -663,6 +671,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -693,6 +702,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -721,6 +731,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -874,6 +885,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/haswellx/hsx-metrics.json b/tools/perf/pmu-events/arch/x86/haswellx/hsx-metrics.json index 11f152c346eb0..a522202cf6844 100644 --- a/tools/perf/pmu-events/arch/x86/haswellx/hsx-metrics.json +++ b/tools/perf/pmu-events/arch/x86/haswellx/hsx-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -161,6 +164,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -254,6 +258,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -263,6 +268,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -272,6 +278,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -281,6 +288,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -664,6 +672,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -704,6 +713,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -732,6 +742,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -905,6 +916,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/icelake/icl-metrics.json b/tools/perf/pmu-events/arch/x86/icelake/icl-metrics.json index f45ae3483df48..1a2154f28b7b5 100644 --- a/tools/perf/pmu-events/arch/x86/icelake/icl-metrics.json +++ b/tools/perf/pmu-events/arch/x86/icelake/icl-metrics.json @@ -115,6 +115,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%" }, @@ -124,6 +125,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -141,6 +143,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -187,6 +190,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -288,6 +292,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 5 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -297,6 +302,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -369,6 +375,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -378,6 +385,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1111,6 +1119,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1164,6 +1173,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1191,6 +1201,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1360,6 +1371,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/icelakex/icx-metrics.json b/tools/perf/pmu-events/arch/x86/icelakex/icx-metrics.json index 0f9b174dfc22a..1ef772b40e045 100644 --- a/tools/perf/pmu-events/arch/x86/icelakex/icx-metrics.json +++ b/tools/perf/pmu-events/arch/x86/icelakex/icx-metrics.json @@ -80,6 +80,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%" }, @@ -89,6 +90,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -106,6 +108,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -152,6 +155,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -253,6 +257,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 5 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -262,6 +267,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -334,6 +340,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -343,6 +350,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1134,6 +1142,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1187,6 +1196,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1214,6 +1224,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1410,6 +1421,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/ivybridge/ivb-metrics.json b/tools/perf/pmu-events/arch/x86/ivybridge/ivb-metrics.json index 5247f69c13b64..11080ccffd514 100644 --- a/tools/perf/pmu-events/arch/x86/ivybridge/ivb-metrics.json +++ b/tools/perf/pmu-events/arch/x86/ivybridge/ivb-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -161,6 +164,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -254,6 +258,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -263,6 +268,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -299,6 +305,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -308,6 +315,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -724,6 +732,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -754,6 +763,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -782,6 +792,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -917,6 +928,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/ivytown/ivt-metrics.json b/tools/perf/pmu-events/arch/x86/ivytown/ivt-metrics.json index 89469b10fa304..65a46d659c0a2 100644 --- a/tools/perf/pmu-events/arch/x86/ivytown/ivt-metrics.json +++ b/tools/perf/pmu-events/arch/x86/ivytown/ivt-metrics.json @@ -103,6 +103,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -112,6 +113,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -122,6 +124,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -161,6 +164,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -254,6 +258,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -263,6 +268,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -299,6 +305,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -308,6 +315,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -725,6 +733,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -765,6 +774,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -793,6 +803,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -948,6 +959,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/jaketown/jkt-metrics.json b/tools/perf/pmu-events/arch/x86/jaketown/jkt-metrics.json index e8f4e5c01c9fb..66a6f657bd6f7 100644 --- a/tools/perf/pmu-events/arch/x86/jaketown/jkt-metrics.json +++ b/tools/perf/pmu-events/arch/x86/jaketown/jkt-metrics.json @@ -76,6 +76,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -85,6 +86,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -95,6 +97,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -114,6 +117,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -160,6 +164,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_lcp", "ScaleUnit": "100%" }, @@ -169,6 +174,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -205,6 +211,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -214,6 +221,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -412,6 +420,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -422,6 +431,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -450,6 +460,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -487,6 +498,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/sandybridge/snb-metrics.json b/tools/perf/pmu-events/arch/x86/sandybridge/snb-metrics.json index 4a99fe515f4b0..4b8bc19392a44 100644 --- a/tools/perf/pmu-events/arch/x86/sandybridge/snb-metrics.json +++ b/tools/perf/pmu-events/arch/x86/sandybridge/snb-metrics.json @@ -76,6 +76,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -85,6 +86,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -95,6 +97,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -114,6 +117,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -160,6 +164,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_lcp", "ScaleUnit": "100%" }, @@ -169,6 +174,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: RS_EVENTS.EMPTY_END", "ScaleUnit": "100%" }, @@ -205,6 +211,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound.", "ScaleUnit": "100%" }, @@ -214,6 +221,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -411,6 +419,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -421,6 +430,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -449,6 +459,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -486,6 +497,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/sapphirerapids/spr-metrics.json b/tools/perf/pmu-events/arch/x86/sapphirerapids/spr-metrics.json index 126300b7ae777..620fc5bd2217d 100644 --- a/tools/perf/pmu-events/arch/x86/sapphirerapids/spr-metrics.json +++ b/tools/perf/pmu-events/arch/x86/sapphirerapids/spr-metrics.json @@ -87,6 +87,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%" }, @@ -96,6 +97,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -105,6 +107,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: TOPDOWN.BR_MISPREDICT_SLOTS. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -151,6 +154,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -252,6 +256,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 6 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -261,6 +266,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -351,6 +357,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -369,6 +376,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences. Sample with: UOPS_RETIRED.HEAVY", "ScaleUnit": "100%" }, @@ -1216,6 +1224,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1269,6 +1278,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1304,6 +1314,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1509,6 +1520,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/skylake/skl-metrics.json b/tools/perf/pmu-events/arch/x86/skylake/skl-metrics.json index a6d212b349f5d..21ef6c9be8167 100644 --- a/tools/perf/pmu-events/arch/x86/skylake/skl-metrics.json +++ b/tools/perf/pmu-events/arch/x86/skylake/skl-metrics.json @@ -101,6 +101,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -110,6 +111,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -120,6 +122,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -167,6 +170,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -271,6 +275,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -280,6 +285,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -345,6 +351,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -363,6 +370,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1065,6 +1073,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1110,6 +1119,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1138,6 +1148,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1343,6 +1354,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/skylakex/skx-metrics.json b/tools/perf/pmu-events/arch/x86/skylakex/skx-metrics.json index fa2f7f126a305..eb6f12c0343d5 100644 --- a/tools/perf/pmu-events/arch/x86/skylakex/skx-metrics.json +++ b/tools/perf/pmu-events/arch/x86/skylakex/skx-metrics.json @@ -101,6 +101,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound.", "ScaleUnit": "100%" }, @@ -110,6 +111,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -120,6 +122,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -167,6 +170,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -271,6 +275,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 4 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -280,6 +285,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -354,6 +360,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -372,6 +379,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1123,6 +1131,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1177,6 +1186,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1205,6 +1215,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1429,6 +1440,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.RETIRE_SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/arch/x86/tigerlake/tgl-metrics.json b/tools/perf/pmu-events/arch/x86/tigerlake/tgl-metrics.json index 4c80d6be6cf1d..b442ed4acfbb4 100644 --- a/tools/perf/pmu-events/arch/x86/tigerlake/tgl-metrics.json +++ b/tools/perf/pmu-events/arch/x86/tigerlake/tgl-metrics.json @@ -109,6 +109,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_backend_bound", "MetricThreshold": "tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where no uops are being delivered due to a lack of required resources for accepting new uops in the Backend. Backend is the portion of the processor core where the out-of-order scheduler dispatches ready uops into their respective execution units; and once completed these uops get retired according to program order. For example; stalls due to data-cache misses or stalls due to the divider unit being overloaded are both categorized under Backend Bound. Backend Bound is further divided into two main categories: Memory Bound and Core Bound. Sample with: TOPDOWN.BACKEND_BOUND_SLOTS", "ScaleUnit": "100%" }, @@ -118,6 +119,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_bad_speculation", "MetricThreshold": "tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots wasted due to incorrect speculations. This include slots used to issue uops that do not eventually get retired and slots for which the issue-pipeline was blocked due to recovery from earlier incorrect speculation. For example; wasted work due to miss-predicted branches are categorized under Bad Speculation category. Incorrect data speculation followed by Memory Ordering Nukes is another example.", "ScaleUnit": "100%" }, @@ -135,6 +137,7 @@ "MetricGroup": "BadSpec;BrMispredicts;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueBM", "MetricName": "tma_branch_mispredicts", "MetricThreshold": "tma_branch_mispredicts > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Branch Misprediction. These slots are either wasted by uops fetched from an incorrectly speculated program path; or stalls when the out-of-order part of the machine needs to recover its state from a speculative path. Sample with: BR_MISP_RETIRED.ALL_BRANCHES. Related metrics: tma_info_branch_misprediction_cost, tma_info_mispredictions, tma_mispredicts_resteers", "ScaleUnit": "100%" }, @@ -181,6 +184,7 @@ "MetricGroup": "Backend;Compute;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_core_bound", "MetricThreshold": "tma_core_bound > 0.1 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where Core non-memory issues were of a bottleneck. Shortage in hardware compute resources; or dependencies in software's instructions are both categorized under Core Bound. Hence it may indicate the machine ran out of an out-of-order resource; certain execution units are overloaded or dependencies in program's data- or instruction-flow are limiting the performance (e.g. FP-chained long-latency arithmetic operations).", "ScaleUnit": "100%" }, @@ -282,6 +286,7 @@ "MetricGroup": "FetchBW;Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group;tma_issueFB", "MetricName": "tma_fetch_bandwidth", "MetricThreshold": "tma_fetch_bandwidth > 0.1 & tma_frontend_bound > 0.15 & tma_info_ipc / 5 > 0.35", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend bandwidth issues. For example; inefficiencies at the instruction decoders; or restrictions for caching in the DSB (decoded uops cache) are categorized under Fetch Bandwidth. In such cases; the Frontend typically delivers suboptimal amount of uops to the Backend. Sample with: FRONTEND_RETIRED.LATENCY_GE_2_BUBBLES_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_1_PS;FRONTEND_RETIRED.LATENCY_GE_2_PS. Related metrics: tma_dsb_switches, tma_info_dsb_coverage, tma_info_dsb_misses, tma_info_iptb, tma_lcp", "ScaleUnit": "100%" }, @@ -291,6 +296,7 @@ "MetricGroup": "Frontend;TmaL2;TopdownL2;tma_L2_group;tma_frontend_bound_group", "MetricName": "tma_fetch_latency", "MetricThreshold": "tma_fetch_latency > 0.1 & tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU was stalled due to Frontend latency issues. For example; instruction-cache misses; iTLB misses or fetch stalls after a branch misprediction are categorized under Frontend Latency. In such cases; the Frontend eventually delivers no uops for some period. Sample with: FRONTEND_RETIRED.LATENCY_GE_16_PS;FRONTEND_RETIRED.LATENCY_GE_8_PS", "ScaleUnit": "100%" }, @@ -363,6 +369,7 @@ "MetricGroup": "PGO;TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_frontend_bound", "MetricThreshold": "tma_frontend_bound > 0.15", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots where the processor's Frontend undersupplies its Backend. Frontend denotes the first part of the processor core responsible to fetch operations that are executed later on by the Backend part. Within the Frontend; a branch predictor predicts the next address to fetch; cache-lines are fetched from the memory subsystem; parsed into instructions; and lastly decoded into micro-operations (uops). Ideally the Frontend can issue Pipeline_Width uops every cycle to the Backend. Frontend Bound denotes unutilized issue-slots when there is no Backend stall; i.e. bubbles where Frontend delivered no uops while Backend could have accepted them. For example; stalls due to instruction-cache misses would be categorized under Frontend Bound. Sample with: FRONTEND_RETIRED.LATENCY_GE_4_PS", "ScaleUnit": "100%" }, @@ -372,6 +379,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_heavy_operations", "MetricThreshold": "tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring heavy-weight operations -- instructions that require two or more uops or micro-coded sequences. This highly-correlates with the uop length of these instructions/sequences.", "ScaleUnit": "100%" }, @@ -1125,6 +1133,7 @@ "MetricGroup": "Retire;TmaL2;TopdownL2;tma_L2_group;tma_retiring_group", "MetricName": "tma_light_operations", "MetricThreshold": "tma_light_operations > 0.6", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots where the CPU was retiring light-weight operations -- instructions that require no more than one uop (micro-operation). This correlates with total number of instructions used by the program. A uops-per-instruction (see UopPI metric) ratio of 1 or less should be expected for decently optimized software running on Intel Core/Xeon products. While this often indicates efficient X86 instructions were executed; high value does not necessarily mean better performance cannot be achieved. Sample with: INST_RETIRED.PREC_DIST", "ScaleUnit": "100%" }, @@ -1178,6 +1187,7 @@ "MetricGroup": "BadSpec;MachineClears;TmaL2;TopdownL2;tma_L2_group;tma_bad_speculation_group;tma_issueMC;tma_issueSyncxn", "MetricName": "tma_machine_clears", "MetricThreshold": "tma_machine_clears > 0.1 & tma_bad_speculation > 0.15", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the CPU has wasted due to Machine Clears. These slots are either wasted by uops fetched prior to the clear; or stalls the out-of-order portion of the machine needs to recover its state after the clear. For example; this can happen due to memory ordering Nukes (e.g. Memory Disambiguation) or Self-Modifying-Code (SMC) nukes. Sample with: MACHINE_CLEARS.COUNT. Related metrics: tma_clears_resteers, tma_contested_accesses, tma_data_sharing, tma_false_sharing, tma_l1_bound, tma_microcode_sequencer, tma_ms_switches, tma_remote_cache", "ScaleUnit": "100%" }, @@ -1205,6 +1215,7 @@ "MetricGroup": "Backend;TmaL2;TopdownL2;tma_L2_group;tma_backend_bound_group", "MetricName": "tma_memory_bound", "MetricThreshold": "tma_memory_bound > 0.2 & tma_backend_bound > 0.2", + "MetricgroupNoGroup": "TopdownL2", "PublicDescription": "This metric represents fraction of slots the Memory subsystem within the Backend was a bottleneck. Memory Bound estimates fraction of slots where pipeline is likely stalled due to demand load or store instructions. This accounts mainly for (1) non-completed in-flight memory demand loads which coincides with execution units starvation; in addition to (2) cases where stores could impose backpressure on the pipeline when many of them get buffered at the same time (less common out of the two).", "ScaleUnit": "100%" }, @@ -1374,6 +1385,7 @@ "MetricGroup": "TmaL1;TopdownL1;tma_L1_group", "MetricName": "tma_retiring", "MetricThreshold": "tma_retiring > 0.7 | tma_heavy_operations > 0.1", + "MetricgroupNoGroup": "TopdownL1", "PublicDescription": "This category represents fraction of slots utilized by useful work i.e. issued uops that eventually get retired. Ideally; all pipeline slots would be attributed to the Retiring category. Retiring of 100% would indicate the maximum Pipeline_Width throughput was achieved. Maximizing Retiring typically increases the Instructions-per-cycle (see IPC metric). Note that a high Retiring value does not necessary mean there is no room for more performance. For example; Heavy-operations or Microcode Assists are categorized under Retiring. They often indicate suboptimal performance and can often be optimized or avoided. Sample with: UOPS_RETIRED.SLOTS", "ScaleUnit": "100%" }, diff --git a/tools/perf/pmu-events/jevents.py b/tools/perf/pmu-events/jevents.py index ca99b9cfe4ada..f57a8f2740257 100755 --- a/tools/perf/pmu-events/jevents.py +++ b/tools/perf/pmu-events/jevents.py @@ -52,7 +52,8 @@ _json_event_attributes = [ # Attributes that are in pmu_metric rather than pmu_event. _json_metric_attributes = [ 'metric_name', 'metric_group', 'metric_expr', 'metric_threshold', 'desc', - 'long_desc', 'unit', 'compat', 'aggr_mode', 'event_grouping' + 'long_desc', 'unit', 'compat', 'metricgroup_no_group', 'aggr_mode', + 'event_grouping' ] # Attributes that are bools or enum int values, encoded as '0', '1',... _json_enum_attributes = ['aggr_mode', 'deprecated', 'event_grouping', 'perpkg'] @@ -303,6 +304,7 @@ class JsonEvent: self.deprecated = jd.get('Deprecated') self.metric_name = jd.get('MetricName') self.metric_group = jd.get('MetricGroup') + self.metricgroup_no_group = jd.get('MetricgroupNoGroup') self.event_grouping = convert_metric_constraint(jd.get('MetricConstraint')) self.metric_expr = None if 'MetricExpr' in jd: diff --git a/tools/perf/pmu-events/pmu-events.h b/tools/perf/pmu-events/pmu-events.h index b7dff8f1021fd..80349685cf4d8 100644 --- a/tools/perf/pmu-events/pmu-events.h +++ b/tools/perf/pmu-events/pmu-events.h @@ -59,6 +59,7 @@ struct pmu_metric { const char *compat; const char *desc; const char *long_desc; + const char *metricgroup_no_group; enum aggr_mode_class aggr_mode; enum metric_event_groups event_grouping; }; diff --git a/tools/perf/util/metricgroup.c b/tools/perf/util/metricgroup.c index c566c68593026..4e7d41d285b4b 100644 --- a/tools/perf/util/metricgroup.c +++ b/tools/perf/util/metricgroup.c @@ -1144,12 +1144,12 @@ static int metricgroup__add_metric_callback(const struct pmu_metric *pm, struct metricgroup__add_metric_data *data = vdata; int ret = 0; - if (pm->metric_expr && - (match_metric(pm->metric_group, data->metric_name) || - match_metric(pm->metric_name, data->metric_name))) { + if (pm->metric_expr && match_pm_metric(pm, data->metric_name)) { + bool metric_no_group = data->metric_no_group || + match_metric(data->metric_name, pm->metricgroup_no_group); data->has_match = true; - ret = add_metric(data->list, pm, data->modifier, data->metric_no_group, + ret = add_metric(data->list, pm, data->modifier, metric_no_group, data->metric_no_threshold, data->user_requested_cpu_list, data->system_wide, /*root_metric=*/NULL, /*visited_metrics=*/NULL, table); -- 2.30.2